Installation Guide
- 15 -
FIG. 21
2-WIRE PLUS GROUND
120 VAC LINE IN
KNOCKOUTS
120VAC 60Hz
LINE-IN
FIG. 22
BOX MARKED
“120VAC INPUT”
CONNECT 
WHITE-TO-WHITE
BLACK-TO-BLACK
GREEN-TO-GROUND
CONNECT THE WIRING
    WARNING: All  electrical wiring 
should be done by a qualifi ed person (s) in 
accordance  with  all  applicable  codes  and 
standards. This range hood must be properly 
grounded.
1.  Remove electrical compartment cover by 
removing (2) screws (Fig.20).
2. Run 2-wire plus ground, 120 VAC electrical 
power cable to the ¾” knockout located on 
the back of the hood. Fig. 21.
3. Remove ¾” electrical knockout from the 
back of the hood.
4. From the electrical box marked “120 VAC Inlet”, 
remove (2) screws that secure the cover to the 
metal wiring box. Fig. 22.
5. Pull 120VAC electrical power cable into the box 
and secure with an appropriate cable clamp.
6. Make electrical connections inside the box. 
Connect white-to-white, black-to-black and 
green-to-ground.
7. Replace the wiring box cover and the screws. 
Reinstall electrical compartment cover and 
screws. Make sure wires are not pinched 
between the cover and box.
FIG. 20
ELECTRICAL 
ELECTRICAL 
COMPARTMENT 
COMPARTMENT 
COVER