Specifications

BEST Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
WT32I SERIES MOUNTING
3”
MIN.
½”
3
15
/
16
7
7
/
8
FRAMING BEHIND
WOOD CROSS
SUPPORT
WOOD CROSS SUPPORT –
SECURED TO FRAMING AND
LOCATED BEHIND DRYWALL
DRYWALL
NOTE: Minimum hood distance above cooktop must not be less than 24”.
A maximum of 30” above the cooktop is highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users’ discretion; and if ceiling height and flue length permit.
CEILING DUCT
MOUNTING DISTANCE ABOVE 36” HIGH COOKTOP (SEE NOTE BELOW)
HEIGHT METHOD
24” 25” 26” 27” 28” 29” 30”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET
DUCTED OR
36-3/4” 37-3/4” 38-3/4” 39-3/4” 40-3/4” 41-3/4” 42-3/4”
NON-DUCTED
9 FEET
DUCTED -- -- -- -- -- -- 42-3/4”
NON-DUCTED -- -- -- -- 40-3/4” 41-3/4” 42-3/4”
10 FEET
DUCTED 38-3/4” 39-3/4” 40-3/4” 41-3/4” 42-3/4”
NON-DUCTED
36-3/4” 37-3/4” 38-3/4” 39-3/4” 40-3/4” 41-3/4” 42-3/4”
MOUNTING BRACKET
LOCATION
(ABOVE 36” HIGH
COOKTOP)
WT32I SERIES WIRING
36 Max.
4-3/8
8-3/4
CENTER LINE OF
DUCT AND HOOD
120 VOLT 60 HZ
GROUNDED WALL OUTLET -
OFFSET FROM DUCT CENTER LINE
(STAY WITHIN 8¾” DIMENSION)