Installation Guide

INDICATOR
LIGHT
Remote Control Functions (Fig.1)
Delay - O
Blower Speed Decrease and O
Blower Speed Increase and On
Light
Press
(Delay) and (Light) buttons together to
Reset Filter Alarm.
English
CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED
BY AN INCORRECT TYPE. DISPOSE OF USED BATTERY IN
ACCORDANCE WITH LOCAL REGULATIONS.
FCC ID: QUS-BESMARTNEW
IC: 11613A-BESMARTNEW
• Changes or modi cations not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
This device complies with Industry Canada license-
exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not
cause interference, and (2) this device must accept any
interference, including interference that may cause
undesired operation of the device.
LINKING PROCEDURE
- The remote must be linked to the range hood in order to
work properly.
- This procedure is also useful if there are two or more products
that can be controlled by means of remote control. For
example, in apartments with adjacent kitchens, showrooms,
fairs, etc.
- If the remote is included with the range hood, this linking
procedure will have already been completed at the factory.
1 - Determine the hood control from list below.
2 - Press
and buttons on the remote simultaneaously
for 5 seconds, until the remote control Indicator Light
turns on. Release
and buttons. Press and
release
button to con rm the linking. At this point
the remote control Indicator Light starts  ashing to
con rm the link is active.
3 - Within 3 seconds press and release the Link Con rm
button on the hood control (see below).
HOOD CONTROLS
Hood Control 1
LINK CONFIRM BUTTON - P1
Hood Control 2
LINK CONFIRM BUTTON - P5
Hood Control 3
LINK CONFIRM BUTTON - P2
Hood Control 6
LINK CONFIRM BUTTON - A
Note: To complete link, press and hold “link con rm button
A until hood user interface light intensity indicator 1 and 3
ash 3 times.
Hood Control 4
LINK CONFIRM BUTTON - P1
FIG. 1
Hood Control 5
LINK CONFIRM BUTTON - P3
ABC D
E
1234 123
SPEED
LIGHTING INTENSITY
Hood Control 7
LINK CONFIRM BUTTON - P5
Note: To complete link, press and hold “P5” for 2 seconds.
P1 P2 P3 P4
P5 P6 P7