SDS
DR
Page 4/10
Trade name: Ni-CD BATTERY
(Contd. of page 3)
· Control parameters
· Ingredients with limit values that require monitoring at the workplace:
1306-19-0 cadmium oxide (nonpyrophoric)
PEL (USA) 0,005 mg/m³
as Cd; see 29 CFR 1910,1027
as Cd; LFC (LOQ 0,1 mg/m3)
0,01* 0,002** mg/m³
REL (USA)
TLV (USA)
as Cd; *inhalable **respirable fraction; BEI
MAK (Germany) einamtembare Fraktion; vgl.Abschn.XIII
7440-02-0 nickel
PEL (USA)
REL (USA)
1 mg/m³
0,015 mg/m³
as Ni; See Pocket Guide App. A
1,5* 0,2** 0,1*** mg/m³
inhal.fraction;*elemental;**insol.,***sol.compds.
TLV (USA)
MAK (Germany) einatembare Fraktion; vgl.Abschn.XIII
1310-58-3 potassium hydroxide
REL (USA)
TLV (USA)
C2 mg/m³
Short-term value: C 2 mg/m³
7440-48-4 cobalt
PEL (USA) 0,1* mg/m³
as Co; *for metal dust & fume, as Co
0,05* mg/m³
inorg. compds.: *metal dust & fume, as Co
0,02 mg/m³
as Co; BEI
REL (USA)
TLV (USA)
MAK (Germany) einatembare Fraktion; vgl.Abschn.XIII
· DNELs: Not available
· PNECs: Not available
· Additional information: The lists valid during the making were used as basis.
· Exposure controls
· Based on the composition shown in Section 3, the following measures are suggested for occupational safety
measure
· Personal protective equipment
· General protective and hygienic measures:
Keep away from foodstuffs, beverages and feed.
Immediately remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
Store protective clothing separately.
Avoid contact with the eyes and skin.
· Respiratory protection:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure
use self-contained respiratory protective device.
· Protection of hands:
Protective gloves
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/
the chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the
degradation
· Material of gloves:
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality
and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the
(Contd. on page 5)