SDS
DR
Page 3/10
Trade name: Ni-CD BATTERY
(Contd. of page 2)
· Information for doctor
· Most important symptoms and effects, both acute and delayed: No further relevant information available.
· Indication of any immediate medical attention and special treatment needed:
No further relevant information available.
5 Firefighting measures
· Extinguishing media
· Suitable extinguishing agents:
CO₂, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
· Special hazards arising from the substance or mixture:
Battery may burst and release hazardous decomposition products when exposed to a fire situation.
· Advice for firefighters Cool fire exposed batteries to prevent rupture.
· Protective equipment: Mouth respiratory protective device.
6 Accidental release measures
· Personal precautions, protective equipment and emergency procedures:
Wear protective equipment. Keep unprotected persons away.
· Environmental precautions:
Do not allow product to reach sewage system or any water sourse.
Inform respective authorities in case of seepage into water course or sewage system.
Do not allow to enter sewers/ surface or ground water.
· Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Use neutralizing agent.
Dispose contaminated material as waste according to item 13.
Ensure adequate ventilation.
· Reference to other sections:
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
7 Handling and storage
· Handling
· Precautions for safe handling:
Ensure good ventilation/exhaustion at the workplace.
Open and handle receptacle with care.
Prevent formation of aerosols.
· Information about fire - and explosion protection: Keep respiratory protective device available.
· Conditions for safe storage, including any incompatibilities
· Requirements to be met by storerooms and receptacles: No special requirements.
· Information about storage in one common storage facility: Not required.
· Further information about storage conditions: Keep container tightly sealed.
· Specific end use(s): No further relevant information available.
8 Exposure controls/personal protection
· Additional information about design of technical facilities: No further data; see item 7.
(Contd. on page 4)
EU