Quick Start Guide

Performance data sheet
Specications
• Temperature: 33~100° F
(0.6~38° C)
• Pressure: 20-100 psi (140-689kPa)
• Capacity: 200 gal (757 L)
• Flow rate: 0.5 gpm (1.9 lpm)
Certications
Replacement Cartridge NO: BE-LGLT800P531
NSF System NO: EFF-6020S
Troubleshooting
My refrigerator is not dispensing water
Make sure that the lter is securely connected to the lter holder. Do not use
tools to tighten the lter in place.
Make sure that the water line to the refrigerator is turned on. The valve must be
completely open for the refrigerator to receive water.
Make sure that the refrigerator door is closed or the dispenser will not work.
My water dispenser is dripping
A few drops are normal. If the water is dripping constantly, have a service
technician check your refrigerators water valve.
My water is cloudy or contains black carbon particles
Cloudy water is caused by microscopic air bubbles. Run two gallons (7.6 L) of
water from your dispenser to clear the air bubbles out.
Black carbon particles in the water are normal and appear with all carbon lters.
Run two gallons (7.6 L) of water through your dispenser to remove loose carbon
particles.
My new lter is making noises or sputtering
Noises and sputtering are caused by trapped air pockets. Run two gallons (7.6 L)
of water from your dispenser to push the air out.
Reinstall the new lter as instructed and make sure that the lter is securely
connected to the lter holder. Do not use tools to tighten the lter in place.
My water tastes bad
If you do not use your water dispenser for more than four days, run two gallons
(7.6 L) of water through the dispenser before using it.
Make sure that you replace your lter every six months to prevent bacteria
growth.
Substance reduction
The system has been tested and certied by the NSF International according to NSFIANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for the water leaving the
system, as specied by NSFIANSI Standards 42 and 53. While testing was performed under standard laboratory
conditions, actual performance may vary.
Tested and Certied by NSF International
against NSF/ANSI Standards 42 and 53 in
Model EFF-6020S for the reduction of the
claims specied on the Performance Data
Sheet.
REPLACEMENT
ELEMENT
V1 ENGLISH 21-0080
One-year limited warranty
Visit
www.bestbuy.com/bestbuyessentials
for details.
Contact Best Buy essentials
For customer service, call 866-597-8427
(U.S. and Canada)
www.bestbuy.com/bestbuyessentials
Best Buy essentials is a trademark of Best Buy and its aliated
companies.
Distributed by Best Buy Purchasing, LLC
7601 Penn Ave South, Richeld, MN 55423 U.S.A.
©2021 Best Buy. All rights reserved.
SUBSTANCE
Chlorine, taste, and
odor
Benzene
Carbofuran
Lead (pH 8.5)
Lead (pH 6.5)
Cyst
Endrin
Mercury (pH 8.5)
Mercury (pH 6.5)
INFLUENT AVERAGE
2.1 mg/L
15 ug/L
73 ug/L
140 ug/L
140 ug/L
120,000 oocysts/L
6 ug/L
6 ug/L
6 ug/L
NSF SPECIFIED CHALLENGE
CONCENTRATION
2.0 mg/L ± 10%
15 ug/L ± 10%
73 ug/L ± 10%
140 ug/L ± 10%
140 ug/L ± 10%
minimum 50000 oocysts/L
6 ug/L ± 10%
6 ug/L ± 10%
6 ug/L ± 10%
AVE. %
REDUCTION
97.0%
96.6%
98.4%
99.6%
99.6%
>99.99%
93.6%
92.3%
93.8%
MAX. PERMISSIBLE
PRODUCT WATER
CONCENTRATION
N/A
0.5 ug/L
40 ug/L
10 ug/L
10 ug/L
N/A
2 ug/L
2 ug/L
2 ug/L
NSF REDUCTION
REQUIREMENTS
≥50%
N/A
N/A
N/A
N/A
≥99.95%
N/A
N/A
N/A
NSF TEST
REPORT
J-00295502
J-00268283
J-00268284
J-00268279
J-00268280
J-00263594
J-00296278
J-00326152
J-00268282
AVERAGE PRODUCT
WATER
CONCENTRATION
0.063 mg/L
0.5 ug/L
2 ug/L
0.5 ug/L
0.5 ug/L
1 oocysts/L
0.3 ug/L
0.5 ug/L
0.3 ug/L