Installation

Installation Instructions for Electronic Stand-Alone Cylindrical Locks
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc.
6
Installing the lock
7 Remove outside lever or knob
1 Insert the control key into the core and rotate the key
15 degrees to the right.
2 Insert a flat blade screwdriver into the figure-8 core
hole and into the lever.
3 Press the screwdriver blade in the direction of the
arrow in Figure 7.
Note: You cannot remove the lever if the screwdriver
blade is inserted too far past the keeper.
4 Slide the lever or knob off of the sleeve.
Caution: Be careful that you do not disconnect
the lever keeper spring.
8 Adjust for door thickness
1 Determine the door’s thickness.
2 Pull the rose locking pin and rotate the outside rose
liner until the proper groove on the through-bolt
stud lines up with the hub face.
83KG, 83KBV, 83KN or 83KZ only:
Using the door as a reference, center the retractor
in the door.
Note 1: Make sure that the locking pin fully locks into
the rose liner.
Note 2: The lockset fits doors 1 3/4 to 2 1/4 thick.
Figure-8
core hole
Figure 7 Removing the outside lever (9K shown)
Insert screwdriver
blade here.
Lever keeper
Figure 8 Adjusting the rose liner for the door thickness
(9KG, 9KBV, 9KN and 9KZ shown)
1 3/4
2
2 1/4
groove
Through-
bolt stud
Hub face
Outside
rose liner
Rose locking
pin