Installation

Installation Instructions for Electronic Stand-Alone Cylindrical Locks
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc.
14
Completing the installation
22 Test lock
For Keypad EZ Locks only:
To test the lock for proper operation before the lock is
programmed, follow these instructions:
1 Press
9998.
2 Press
#.
The green light flashes and the locking mechanism
unlocks.
3 Turn the lever and open the door.
For B.A.S.I.S. and NT500 Locks only:
B.A.S.I.S. locks, by default, are set to run in cylindrical
mode. A temporary operator card is provided for testing
the lock and it will be deleted after programming.
1 Use the temporary operator card to test the lock.
The green light flashes and the unit locks and relocks
after three seconds.
2 Check the handle to make sure the lock unlocks and
then relocks.
If the mechanism doesn’t unlock, refer to the following
table. For additional troubleshooting instructions, see
the Electronic Stand-Alone Locks Service Manual.
LEDs Sounder You should
Single
red flash
Use the card at a moderate
speed.
Red
flashes
3 short
tones
Use the temporary operator
card provided with the lock.
Green
flashes
Check the motor connection.
Check the battery connection.