Installation

Installation Instructions for Electronic Stand-Alone Cylindrical Locks
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc.
10
Installing the lock
15 Route wires on fire plate
1 Route the motor connector wires underneath the
side tabs, as shown in Figure 15.
2 Optional: Keypad EZ Only: Route the Keypad EZ
wires underneath the side tabs.
3 Route the battery connector wire above the side
tabs.
16 Make motor connection
1 From the inside of the door, connect the motor
connector from the chassis to its mating connector
on the wire harness, as shown in Figure 16.
Note: The motor connection has 2 wires and 2 pins.
The wire colors are yellow and gray.
Caution: When making the motor connection,
make sure:
there are no loose wire connections where the
wires are inserted into the connectors
the connectors are firmly mated.
2 Optional: Keypad EZ Only: Make the remote unlock
connections with wire nuts or crimp connectors.
See the Installation Instructions for Keypad EZ Remote
Unlock (T80922) for more information.
Figure 15 Routing the wires on the fire plate
Inside of door
Motor connector
Battery connector
Side tabs
Battery holding
tabs
Figure 16 Making the motor connection
Inside of door
Motor connector