Service manual
Installation Instructions for B.A.S.I.S. Cylindrical Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
12
Completing the installation
19 Test lock
To test the lock for proper operation before the lock is
programmed, use the temporary operator card that came
with the lock. This card is for temporary use only. After
permanent cards have been programmed for the lock, the
temporary card should be deleted.
1 Use the temporary operator card to activate the lock.
When the lock detect the presence of a card for the
first time, it performs a series of diagnostic self-tests. If
no problem is detected, the lock responds with 4 red
LED flashes, simultaneous with 4 green LED flashes
and 4 short tones.
If a problem is detected, the lock’s red LED and
green LED simultaneously flash in a repeating pattern
(and no tones sound). The lock’s control electronics
board must be replaced. For instructions, see the
B.A.S.I.S. G Service Manual (T63300) or the B.A.S.I.S. V
Service Manual (T61805).
Note: If the lock has a proximity card reader, it may have
already been activated by the presence of an object near
the card reader.
2 Use the temporary operator card to access the lock.
The green light flashes and the locking mechanism
unlocks.
3 Turn the lever and open the door.
4 With the door closed, insert and turn the key to
unlatch the door.
If the mechanism doesn’t unlock, refer to the
following table. For additional troubleshooting
instructions, see the B.A.S.I.S. G Service Manual or the
B.A.S.I.S. V Service Manual.
LEDs Sounder You should
Single
red flash
— Use the card at a moderate speed.
Red
flashes
3 short
tones
Use the temporary operator card
provided with the lock.
Green
flashes
— Check the motor connection.
— — Check the battery connection.
© 2002 Best Lock Corporation dba Best Access Systems.
T61835/Rev – 1854203 ER-7991-12 February 2002