Servicing Standard Mortise Case Parts
B.A.S.I.S. V Service Manual 6–7
7. Insert the motor module’s actuator into the opening in the locking
bar. See Figure 6.5. Rotate the components into place. The motor
module locks into place in the case. The locking bar fits into the slot
on the outside hub. The two feet on the bottom of the locking bar
fit into the bottom of the case.
Turning over the cylinder clamp plate
Turn over the cylinder clamp plate and insert it in the case.
See Figure 6.4.
Note: The screw must be on the same side of the case as the cylinder.
Figure 6.5 Motor module and locking bar in place
Outside hub
Locking bar
Motor module’s