Specifications
8
IDH Max
®
& ELECTRO
40HW ELECTRIfIED – HOW TO ORDER
RQE
45HW– lever
47HW– lever
high security
45HW/47HW:
DEL– single key
latch, fail safe
DEU– single key
latch, fail secure
WEL– double key
latch, fail safe
WEU– double key
latch, fail secure
TDEL– single key
deadbolt, fail safe
TDEU– single key
deadbolt, fail
secure
TWEL–double key
deadbolt, fail safe
TWEU–double key
deadbolt, fail
secure
45HW only:
NXEL– keyless, latch,
fail safe
NXEU– keyless, latch,
fail secure
LEL– keyless, deadbolt,
fail safe
LEU– keyless, deadbolt,
fail secure
45HW:
605 606
611 612
613 618
619 625
626 690
47HW:
626 630
AL – abrasive lever
IDH – integrated door
hardware w/RQE & DS
LL – lead lined
LS – latch status
DS – door status
RQE – request to exit
SH – security head screws
TL – tactile lever
Thick Door –
specify thickness if other
than 1
3
/
4
"
(1
3
/
4
" min. x 4" max)
Must specify: 24V or 12V
45HW:
H– 2
3
/
4
" flat
J– wrought
M– forged
N
– forged
con cealed
cylinder
S– 3
1
/
2
" flat
R– 2
3
/
4
"
concave
47HW:
M– forged
RH
RHRB
LH
LHRB
45HW:
0– keyless
or less
cylinder,
7– 7 pin
47HW:
7– 7 pin
(accepts
5C cores
only)
* “N” trim not available on double keyed functions. **Must specify key mark and number of keys or designate L/C for less core.
†
See H Series catalog for details.
45HW
Series
7
Core
Housing
Func tion
NXEU 12 J
Lever
Style
Trim
Style
(page 11) (page 3)(pages 8–9)
612
Finishes
†
LH
Hand ing
Options
†
40HW ELECTRIfIED – fUNCTIONs
%" >%"
(page 11)
Levers:
3– solid tube/
return
12– solid tube/
no return
14– curved
return
15– contour/
angle return
16– curved/no
return
17– gullwing no
return
Knobs:
4– round
Latch
Function
Locked by Unlocked by Locked by Unlocked by
Inside Knob or LeverOutside Knob or Lever
Operated by
%" >#"!
• Inside and Outside
knob/lever when power
is removed from the
solenoid
• Inside/Outside key
Latchbolt is
deadlocked by an
auxiliary latch
Applying power to
solenoid; remains locked
while power is on
Removing power from
solenoid
Applying power to the
solenoid; remains
locked while power is
on
Removing power
from the solenoid
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature co
ntrol module (TCM) included.
Temperature control module (TCM) included.
• Inside and Outside
knob/lever when power
is applied to the solenoid
• Inside/Outside key
Latchbolt is
deadlocked by an
auxiliary latch
Removing power from
solenoid
Applying power to solenoid;
remains unlocked while
power is on
Removing power from
solenoid
Applying power to
solenoid; remains
unlocked while
power is on
DEL–Locked
Fail Safe
DEU–Unlocked
Fail Secure
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Temperature control module (TCM) included.
WEL–Locked
Fail Safe
WEU–Un locked
Fail Secure
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously.
Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Removing voltage locks inside & outside knobs/levers simultaneously.
Temperature control module (TCM) included.
• Outside knob/lever
when power is removed
from the solenoid
• Outside key
• Inside knob/lever.
Latchbolt is
deadlocked by an
auxiliary latch
Applying power to
solenoid; remains locked
while power is on
Removing power from
solenoid
Cannot be locked Always unlocked
Removing power from
solenoid
Applying power to solenoid;
remains unlocked while
power is on
Cannot be locked Always unlocked• Outside knob/lever
when power is applied
to the solenoid
• Outside key
• Inside knob/lever.
Latchbolt is
deadlocked by an
auxiliary latch
Lock Voltage