9KM IDH MAX
®
-FUNCTIONS
Inside Knob or Lever
DDEL–Locked
Rotating the inside knob/lever,
Rotating the outside knob/lever—
only when power is off,
Turning the key in the outside
knob/lever.
Applying 12 volts DC.
The outside knob/lever
remains locked only
while power is on.
Cannot be locked
Always unlocked
DDEU–Un locked
Rotating the inside
knob/lever,
Rotating the outside
knob/lever—only when
power is on,
Turning the key in the out
side knob/lever.
Switchin
g off
1
2 volts DC
Switching off
12 volts DC
Applying 12 volts DC.
The outside
knob/lever remains
unlocked only while
power is off.
Cannot be locked
Always unlocked
Function
Latch
Operated by
Outside Knob or Lever
Locked by Unlocked by Locked by
Unlocked by
Shading indicates a
ridged lever/knob in a
non-energized state.
9KM IDHMAX
®
– FUNCTIONS
Powered by 12V DC. Temperature control module (TCM) is not needed.
40HW ELECTRIFIED- SPECIFICATIONS ELECTRIFIED-INTRO
40HW Mortise
Electrically-Operated Lockset
Types:
12 volts AC or DC — 0.60 amps
24 volts AC or DC — 0.45 amps
All EU functions: Electrically Unlocked (Fail Secure)
All EL functions: Electrically Locked (Fail Safe)
Approval Listings:
UL listed for GYQS Electrically-controlled singlepoint locks or latches.
This product has been approved by the California State Fire Marshal (CSFM)
pursuant to section 13144.1 of the California Health and Safety Code.
Approved by the city of New York Board of Stan dards and Appeals under
calendar number 49-88-SA. See CSFM listing No. 4136-1175:101 for
al low able values and/or conditions fo use concerning material pre sent ed in
this doc u ment. It is subject to re-examination,revisions and possible
cancellation.
NOTE: All W-series locks require the use of a (TCM) Temperature Control Module.
A TCM and TCM connector are supplied standard with every order.
The 40HW, 8KW, and 9KW electromechanical locks provide fail-safe (electrically locked) and fail-secure
(electrically unlocked) operation. They also provide a way to lock and unlock the door from a remote
location for safety, security, or convenience through an individual switch, switch lock, relay, access control
system, or other automatic control system. More importantly, these locks exhibit the same features and
meet the same standards and specifications as our mechanical 40H mortise and 8K/9K heavy duty
cylindrical locksets.
Powered by 12V DC. Temperature control module (TCM) is not needed.
40HW ELECTRIFIED – SPECIFICATIONS
40HW/8KW/9KW ELECTRIFIED LOCK INTRODUCTION