Specifications
Lock Voltage
NOTE: 8KW/9KW Electromechanical locksets are intended for use on minimum 1
3
/
4
"
thick doors. Consult your local Stanley office when in stall ing 8KW/9KW
electromechanical locksets on doors less than 1
3
/
4
" thick.
NOTE: All W-series locks require the use of a (TCM) Temperature Control Module.
A TCM and TCM connector are supplied standard with every order.
10
IDH Max
®
& ELECTRO
%<1/3+6/*(11,*86/*(11<5,6(8,+4*07,8
%%" ! > !"!
%%" !>#"!
Inside Knob or Lever
DEL-Locked
Applying power to the
solenoid; remains
locked while power is
on.
Removing power from the
solenoid
Cannot be locked. Always unlocked.
DEU-Un locked
• Rotating the inside
knob/lever,
• Rotating the outside
knob/lever—only when
power is on,
• Turning the key in the
outside knob/lever.
Removing power from the
solenoid
Applying power to the
solenoid; remains locked
while power is on.
Cannot be locked.
Always unlocked.
Locks are powered by 12 or 24 volts AC/DC at 500mA max. or 0.18 amps. Temperature control module (TCM) included
Locks are powered by 12 or 24 volts AC/DC at .50amps max. or 0.18 amps. Temperature control module (TCM) included
Function Latch
Operated by
Outside Knob or Lever
Locked by Unlocked by Locked by Unlocked by
8kW/9kW – fUNCTIONs
8kW/9kW – sPECIfICaTIONs
Shading indicates a ridged lever/ knob in a non-energized state.
8
KW:
4– round
6– tulip
9KW:
14– curved
return
15– contour
angle
return
16– curved
no return
* Handles are made from a zinc alloy, and have been plated to be equivalent in appearance to the finishes listed.
TL
8KW:
83KW– 2
3
/
4
"
84KW– 3
3
/
4
"
85KW– 5"
9KW:
93KW– 2
3
/
4
"
94KW– 3
3
/
4
"
95KW– 5"
0– keyless
7– 7 pin
housing
accepts
all BEST
cores
DEU–
electrically-
unlocked
DEL–
electrically-
locked
C– 3" convex
D– 3
1
/
2
" convex
K– 3" convex—
no ring
L– 3
1
/
2
" convex
—no ring
STK–
2
3
/
4
" ANSI
S3–
4
7
/
8
" ANSI
605 606
611 612
613 618
619 625
626 690
%%" !>%"
93KW
Series
7
Core
Housing
DEU
Func tion
14
Knob/Lever
Style
K
Trim
Style
STK 626
Strike
Package
Finishes* Options
8kW/9kW – HOW TO ORDER
(page 11) ( page 11) ( page 3)(See Below)
• Rotating the inside
knob/lever
• Rotating the outside
knob/lever—only when
power is off
• Turning the key in the
outside knob/lever.
Types:
• 12 volts AC/DC when used with supplied TCM — 0.50 amps
• 24 volts AC/DC when used with supplied TCM — 0.18 amps
• All EU functions: Electrically Unlocked (Fail Secure)
• All EL functions: Electrically Locked (Fail Safe)
Approval Listings:
• UL listed for GYQS Elec tri cal ly-controlled singlepoint locks or latches.
• This product has been approved by the California State Fire Marshal (CSFM)
pur su ant to section 13144.1 of the California Health and Safety Code.
• Approved by the city of New York Board of Standards and Appeals under
calendar number 730-89-SA. See CSFM listing No. 4136-1175:103. It is
subject to re-examination, revision and possible cancellation.
8KW only:
BRK– breakaway knob
KNL– knurled knob
TAC– tactile knob
9KW only:
AL– abrasive lever
LM– lost motion
RQE– request-to-exit
TL– tactile lever
Note: specify inside (I), outside
(O), or both (B) for AL, TL, TAC,
KNL options
8KW & 9KW:
LL– lead lined
SH– security head screws
3
/
4
–
3
/
4
" throw latch
Must specify: 24V or 12V