Specifications

Lock Voltage
NOTE: 8KW/9KW Electromechanical locksets are intended for use on minimum 1
3
/
4
"
thick doors. Consult your local Stanley office when in stall ing 8KW/9KW
electromechanical locksets on doors less than 1
3
/
4
" thick.
NOTE: All W-series locks require the use of a (TCM) Temperature Control Module.
A TCM and TCM connector are supplied standard with every order.
10
IDH Max
®
& ELECTRO
%<1/3+6/*(11,*86/*(11<5,6(8,+4*07,8
%%" ! > !"!
%%" !>#"!
Inside Knob or Lever
DEL-Locked
Applying power to the
solenoid; remains
locked while power is
on.
Removing power from the
solenoid
Cannot be locked. Always unlocked.
DEU-Un locked
Rotating the inside
knob/lever,
Rotating the outside
knob/lever—only when
power is on,
Turning the key in the
outside knob/lever.
Removing power from the
solenoid
Applying power to the
solenoid; remains locked
while power is on.
Cannot be locked.
Always unlocked.
Locks are powered by 12 or 24 volts AC/DC at 500mA max. or 0.18 amps. Temperature control module (TCM) included
Locks are powered by 12 or 24 volts AC/DC at .50amps max. or 0.18 amps. Temperature control module (TCM) included
Function Latch
Operated by
Outside Knob or Lever
Locked by Unlocked by Locked by Unlocked by
8kW/9kW – fUNCTIONs
8kW/9kW – sPECIfICaTIONs
Shading indicates a ridged lever/ knob in a non-energized state.
8
KW:
4 round
6 tulip
9KW:
14– curved
return
15– contour
angle
return
16– curved
no return
* Handles are made from a zinc alloy, and have been plated to be equivalent in appearance to the finishes listed.
TL
8KW:
83KW– 2
3
/
4
"
84KW– 3
3
/
4
"
85KW– 5"
9KW:
93KW– 2
3
/
4
"
94KW– 3
3
/
4
"
95KW– 5"
0– keyless
7– 7 pin
housing
accepts
all BEST
cores
DEU
electrically-
unlocked
DEL
electrically-
locked
C– 3" convex
D– 3
1
/
2
" convex
K– 3" convex—
no ring
L– 3
1
/
2
" convex
—no ring
STK
2
3
/
4
" ANSI
S3
4
7
/
8
" ANSI
605 606
611 612
613 618
619 625
626 690
%%" !>%" 
93KW
Series
7
Core
Housing
DEU
Func tion
14
Knob/Lever
Style
K
Trim
Style
STK 626
Strike
Package
Finishes* Options
8kW/9kW – HOW TO ORDER
(page 11) ( page 11) ( page 3)(See Below)
Rotating the inside
knob/lever
Rotating the outside
knob/lever—only when
power is off
Turning the key in the
outside knob/lever.
Types:
12 volts AC/DC when used with supplied TCM0.50 amps
24 volts AC/DC when used with supplied TCM0.18 amps
All EU functions: Electrically Unlocked (Fail Secure)
All EL functions: Electrically Locked (Fail Safe)
Approval Listings:
UL listed for GYQS Elec tri cal ly-controlled singlepoint locks or latches.
This product has been approved by the California State Fire Marshal (CSFM)
pur su ant to section 13144.1 of the California Health and Safety Code.
Approved by the city of New York Board of Standards and Appeals under
calendar number 730-89-SA. See CSFM listing No. 4136-1175:103. It is
subject to re-examination, revision and possible cancellation.
8KW only:
BRK– breakaway knob
KNL– knurled knob
TAC– tactile knob
9KW only:
AL abrasive lever
LM– lost motion
RQErequest-to-exit
TL tactile lever
Note: specify inside (I), outside
(O), or both (B) for AL, TL, TAC,
KNL options
8KW & 9KW:
LL lead lined
SH security head screws
3
/
4
3
/
4
" throw latch
Must specify: 24V or 12V