Specifications

Lithonia Lighting
Fluorescent
One Lithonia Way, Conyers, GA 30012
Phone: 800-858-7763 Fax: 770-929-8789
www.lithonia.com
10˚ 30˚
50˚
70˚
90˚
90˚
200
400
600
800
1000
1200
1400
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 70%50%30% 50%30%10% 50%30%10%
50
46
42
38
35
32
30
28
26
24
23
50
44
39
34
30
27
24
22
20
19
17
50
42
36
31
26
23
21
18
17
15
14
49
43
38
33
30
26
24
22
20
18
17
49
41
35
30
26
23
20
18
17
15
14
49
40
33
28
24
20
18
16
14
13
12
47
41
36
32
29
26
23
21
19
18
16
47
40
34
29
26
23
20
18
16
15
14
47
39
32
27
23
20
18
16
14
13
12
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0˚ - 30˚
0˚ - 40˚
0˚ - 60˚
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
1051
1697
2907
3606
0
3606
12.3
19.9
34.0
42.2
0.0
42.2
29.2
47.1
80.6
100.0
0.0
100.0
Efficiency: 42.2%
CP Summary
90
15˚
25˚
35˚
45˚
55˚
65˚
75˚
85˚
90
1377
1380
1309
1171
974
745
511
297
134
33
0
1377
1370
1317
1223
1090
920
728
514
254
54
0
10˚ 30˚
50˚
70˚
90˚
90˚
200
400
600
800
1000
1200
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 70%50%30% 50%30%10% 50%30%10%
81
74
67
61
56
51
47
44
41
38
36
81
71
61
54
47
42
38
34
31
29
26
81
68
57
48
41
36
32
28
25
23
21
79
69
60
53
46
41
37
34
31
28
26
79
66
56
47
41
36
31
28
25
23
21
79
64
52
43
36
31
27
24
21
19
17
76
66
58
50
45
40
36
33
30
27
25
76
64
54
46
40
35
31
27
25
22
21
76
62
51
42
36
31
27
24
21
19
17
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0˚ - 30˚
0˚ - 40˚
0˚ - 60˚
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
1010
1669
3015
3882
0
3882
17.7
29.3
52.9
68.1
0.0
68.1
26.0
43.0
77.7
100.0
0.0
100.0
Efficiency: 68.1%
CP Summary
90
15˚
25˚
35˚
45˚
55˚
65˚
75˚
85˚
90
1280
1279
1233
1141
1005
828
623
406
211
46
0
1280
1277
1253
1194
1101
969
806
590
291
64
0
10˚ 30˚
50˚
70˚
90˚
90˚
300
600
900
1200
1500
1800
Coefficients of Utilization
pf 20%
pc 80% 70% 50%
pw 70%50%30% 50%30%10% 50%30%10%
81
74
67
61
56
51
47
44
41
38
36
81
71
62
54
48
42
38
34
31
29
27
81
68
57
48
41
36
32
28
26
23
21
79
69
60
53
47
42
37
34
31
28
26
79
67
56
47
41
36
32
28
25
23
21
79
64
52
43
37
31
27
24
21
19
17
76
66
58
51
45
40
36
33
30
28
26
76
64
54
46
40
35
31
28
25
23
21
76
62
51
42
36
31
27
24
21
19
17
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0˚ - 30˚
0˚ - 40˚
0˚ - 60˚
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
1529
2527
4552
5837
0
5837
17.9
29.6
53.2
68.3
0.0
68.3
26.2
43.3
78.0
100.0
0.0
100.0
Efficiency: 68.3%
CP Summary
90
15˚
25˚
35˚
45˚
55˚
65˚
75˚
85˚
90
1934
1941
1880
1747
1539
1275
956
611
298
66
0
1934
1913
1871
1781
1632
1435
1179
849
431
90
0
2AV 2x4 Direct/Indirect Lighting
2AV G 2 32 MDR, (2) 32W T8 lamps, 2850 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL 10121
2AV G 3 32 MDR, (3) 32W T8 lamps, 2850 lumens per lamp, s/m 1.3 (along) 1.3 (across), test no. LTL 10155
2AV G 3 32 MDR ASR, (3) 32W T8 lamps, 2850 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL 10120
Sheet #: 2AV 2X4 T8
©2007-2010 Acuity Brands Lighting, Inc. All rights reserved. Rev. 11/22/10
MOUNTING DATA
*DGA accessory available to provide ceiling trim flange and fixture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA installation is 24-3/4" x 48-3/4" (Tolerance is +1/8", -0”).
For additional photometric information, visit our website at 'lithonia.com'.
Appropriate
Ceiling Type Trim Type
Exposed grid tee (1' and 9/16") G
Concealed grid tee G
Screw slot ST
Plaster or plasterboard G*
STAGASTG
Screw Slot (scre w slot tee)Lay-in trim (exposed grid teeLay-in trim (exposed grid tee Screw slot trim (screw slot tee)
)