Design Guide
60 bertazzoni.com
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the
appliances and the adjacent cabinets, special side profiles are
factory-installed and covering frames are provided with the
product.
For panel ready columns, do not exceed the maximum
weight of 75 pounds (34 kg) for door panel. Panel can have
thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliances must be performed in
accordance with the provisions of applicable legislation.
Be sure that support of these appliances is perpendicular to
the front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting
the weight of all the appliances when in use. Please see any
single product installation manual for required floor support.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
TOP VIEW
FRONT VIEW
E E
E
EE E
5"
127
MAX
A separate 10 Amp circuit breaker servicing only these
appliances is recommended.
PLUMBING REQUIREMENTS
Bertazzoni Freezer Columns are provided with a water filter
assembly which must be mounted outside the unit.
The appliance must be connected only to a potable water
supply system.
To connect to water supply system (for appliances equipped
with ice maker) a ¼” waterline with accessible shut-off valve
must be supplied.
The solenoid connection on the appliance is ¾” diameter but
is metric threaded (NPT).
The system pressure must be between from 8 PSI to 75 PSI
(between 0.5 bar and 5 bar). Different pressures can cause
malfunctions or leaks in the water system.
For information on how to purchase the water filter, please
see Use and Maintenance Manual.
Multiple installations
Installation requirements
MULTIPLE INSTALLATIONS
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.