Design Guide
19bertazzoni.com
INSTALLATION
All Bertazzoni columns can be installed in a standard 25”
depth cutout.
Finish the edges of the opening because they may be visible
when the door is open.
For a built-in installation, to cover gaps between the appliance
and the adjacent cabinets, special side profiles are factory-
installed and covering frames are provided with the product.
For instructions of product combinations please see the
Multiple Installation Section (page 58).
CABINET REQUIREMENT
Installation of the appliance must be performed in accordance
with the provisions of applicable legislation.
Be sure that support of this appliance is perpendicular to the
front facing of the wall or cabinet before you perform the
installation.
The floor must be flat and must be capable of supporting the
weight of the appliance when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly - grounded horizontally - mounted electrical
receptacle should be installed.
Place the electrical supply flush with the back wall and within
the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet
depth.
TOP VIEW
FRONT VIEW
E E
E
EE E
5"
127
MAX
A separate circuit breaker servicing only this appliance is
recommended.
24” Refrigerator Column Panel Installed
Installation requirements
BUILT-IN REFRIGERATOR COLUMNS
Required floor support 992 lb (450 kg ) Electrical supply 115 V 60 Hz 163 W 1.5 Amp
Service 15 Amp dedicated circuit
Power Connection NEMA 5 -15P with 79” power cord
For detailed installation specifications consult the multiple installation
requirements page or each single product installation manual.
Dimensions in parentheses are millimeters unless otherwise specified.