Installation
20
GAS CONVERSION
Warning!
Before carrying out this operation, disconnect the 
appliance from gas and electricity.
Gas  conversion  shall  be  conducted  by  a  fac-
tory-trained professional.
Call the customer service hotline to identify a fac-
tory-trained professional near your home.
The gas conversion procedure  for this range in-
cludes 6 steps:
 • Pressure regulator
 • Surface burners
 • Oven burner
 • Broiler burner
 • Visual checks prior  to  closure  of  oven bottom 
panel
 • Adjustment of minimum setting 
The conversion is not completed if all 6 steps have 
not been concluded properly.
Before performing the gas conversion, locate the 
package containing the replacement nozzle ship-
ped with every range.
IMPORTANT: Each nozzle has a number indica-
ting its fl ow diameter printed on the body. Consult 
the table number 1 for matching nozzles to bur-
ners.
Save the nozzles removed from the range for fu-
ture use.
Step 1: pressure regulator
The pressure regulator supplied with the applian-
ce is a convertible type pressure regulator for use 
with Natural Gas at a nominal outlet pressure of 
4” w.c. or LP gas at a nominal outlet pressure of 
11” w.c. and it is pre-arranged from the factory to 
operate with one of these gas/pressure as indica-
ted in the labels affi xed on the appliance, package 
and Instruction booklet.
To convert the regulator for use with the other gas:
Unscrew  by  hand  the  upper  cap  of  the  regula-
tor, remove the white plastic attachment from the 
cap, reverse its direction and screw it again fi rm-
ly against the  cap. The  white plastic attachment 
has arrows indicating the position for natural gas 
(NAT) and LP gas (LP).
Screw by hand the metal cap in the original posi-
tion on the regulator.
Step 2: surface burners
To replace the nozzles of the surface burners, lift 
up the burners and unscrew the nozzles shipped 
with the range using a 7 mm (sochet wrench). 
Replace  nozzles  using  the  conversion  set  sup-
plied  with  the  range  or by  a Bertazzoni  authori-
zed parts warehouse. Each nozzle has a number 
indicating  its  fl ow  diameter  printed on  the  body. 
Consult the table number 1 and matching nozzles 
to burners. 
/ Gas conversion
LP
NAT