Installation Manual Self Clean Oven Ranges
15
/ Gas connection
PRESSURE REGULATOR
Since  service  pressure  may  fl uctuate  with  local 
demand,  every  gas  cooking  appliance  must  be 
equipped with  a  pressure  regulator  on  the  inco-
ming service line for safe and effi cient operation.
The pressure regulator shipped with the applian-
ce has two female threads ½” NPT. The regulator 
shall be installed properly in order to be accessible 
when the appliance is installed in its fi nal position.
Manifold pressure should be checked with a ma-
nometer and comply with the values indicated be-
low:
Natural gas 4.0” W.c.P. 
LP/Propane 11.0” W.C.P. 
Incoming line  pressure  upstream from  the  regu-
lator must be 1” W.c.P. higher than the manifold 
pressure in order to check the regulator. 
The regulator used on this range can withstand a 
maximum input pressure of 1/2 PSI (13,8” w.c. or 
3,5 kPa) If the line pressure exceeds that amount, 
a stepdown regulator is required.
The  appliance,  its  individual  shut-off  valve,  and 
the pressure regulator must be disconnected from 
the gas line during any pressure testing of that sy-
stem at pressures in excess of 1/2 PSI (13,8” w.c. 
or 3,5 kPa).
The individuaL manual shut-off valve must be in 
the  OFF  position  during  any  pressure  testing of 
the  gas  supply  piping  system  at  test  pressures 
equal  to  or  less  than  1/2  PSI  (13,8”  w.c.  or  3,5 
kPa).
Warning
Before  carrying  out  any servicing  operation di-
sconnect  the  appliance  from  gas  and  electric 
supply and extra appliance from fi nal installation 
place in order to have access to the appliance for 
proper servicing intervention.