User Manual

11
5) Remove damaged supply cord set by taking
off the 4 electrical connection screws (block
L1,N,L2andGroundscrew,seediagram)
6) Insert the new supply cord set in the strain
relief and lock it with two strain relief's
screwsinsuitableposition.
7) Fix well thering
terminals G, L1, N, L2 of the
new supply cord set asshown in diagram
withits4screws
8) Reinstall the back enclosure panel with 6
screws
9) Slide the appliance back into its proper
location
10) Reconnect the appliance to the electrical
power.
ELECTRICALGROUNDING
Thisapplianceisequippedwithafourprongplug
for your protection against shock hazard and
should be plugged directly into a properly
grounded receptacle. Do not cut or remove the
groundingprongfromthisplug.
WARNING!
ELECTRICALSHOCKHAZARD
Disconnectelectricalpowe ratthecircuit
breakerbox
orfuseboxbeforeinstallingthe
appliance.
Provideappropriategroundfortheappliance.
Usecopperconductorsonly.
Failuretofollowtheseinstructionscouldresult
inseriousinjuryordeath
CAUTION
Labelallwirespriortodisconnectingwhen
servicingcontrols.Wiringerrorscancause
improperanddangerousoperation.
Verifyproperoperation
afterservicing
APPLIANCESERVING
Beforecarryinganyservicingoperation
disconnecttheappliancefromgasandelectric
supplyandextraappliancefromfinal
installationplaceinordertohaveaccesstothe
applianceforproperservicingintervention.