5) Remove damaged supply cord set by taking
off the 4 electrical connection screws (block
L1,N,L2andGroundscrew,seediagram)
6) Insert the new supply cord set in the strain
relief and lock it with two strain relief's
screwsinsuitableposition.
7) Fix well thering
terminals G, L1, N, L2 of the
new supply cord set asshown in diagram
withits4screws
8) Re‐install the back enclosure panel with 6
screws
9) Slide the appliance back into its proper
location
10) Re‐connect the appliance to the electrical
power.
ELECTRICALGROUNDING
Thisapplianceisequippedwithafour‐prongplug
for your protection against shock hazard and
should be plugged directly into a properly
grounded receptacle. Do not cut or remove the
groundingprongfromthisplug.
WARNING!
ELECTRICALSHOCKHAZARD
Disconnectelectricalpowe ratthecircuit
breakerbox
orfuseboxbeforeinstallingthe
appliance.
Provideappropriategroundfortheappliance.
Usecopperconductorsonly.
Failuretofollowtheseinstructionscouldresult
inseriousinjuryordeath
CAUTION
Labelallwirespriortodisconnectingwhen
servicingcontrols.Wiringerrorscancause
improperanddangerousoperation.
Verifyproperoperation
afterservicing
APPLIANCESERVING
Beforecarryinganyservicingoperation
disconnecttheappliancefromgasandelectric
supplyandextraappliancefromfinal
installationplaceinordertohaveaccesstothe
applianceforproperservicingintervention.