User Manual

10
ELECTRICALCONNECTION
The appliance shall be connected toa single
phase electric line rated at 120/208Vac or
120/240Vacand60Hzfrequency.
Electricpowerrating:
‐120/208Vac:11800Wattor53Amax.
‐120/240Vac:12900Wattor56Amax.
Ovenheatingelementspowerrating:
‐Ovenbakeelement=2100Watt
‐Oven
circularelement=3300Watt
‐Ovenbroilelement=3400Watt
Inductionheatingelements powerrating:
‐
210inductionelement=2300–3700Watt
‐
180 induction element = 1850 – 3000 Watt
(nr.2zones)
‐
145inductionelement=1400–2200Watt
Installasuitableelectricpowersupplyreceptacle
connection typeNEMA 14‐50R able to support a
load of atleast 50 A (per line) according to local
coderequirements.Forfourorthreewirespower
supplyconnectionsystemseediagrambelow.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options
belowshould be usedin grounding the
receptaclepowersupplyconnections.
OPTION 1 – FOUR Wires connection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrica l supply wire (L1‐hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2‐hot
wire)
‐ Connect the NEUTRAL receptacle terminal to
the incoming NEUTRAL (WHITE) electrical
supplywire
‐ Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical
supplywire
OPTION2‐THREE‐Wiresconnection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrica l supply wire (L1‐hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2‐hot
wire)
‐ Connect the NEUTRAL with the GROUND
receptacle terminal to the incoming NEUTRAL
(WHITE)electrical
supplywire
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCEASITMAYRESULTINFIRE,ELECTRIC
SHOCKOROTHERtypeofPERSONALINJURY.
The appliance isequipped at the factory with an
electric supply cord set 4 wires type with ring
terminals (L1, L2, N, Ground) suitable for range
use UL/CSA listed typ e SRDT/DRT 2x6AWG (L1,
L2)+2x8AWG (N, G) rated 300V, 50A with fused
plug type NEMA 14‐50P; cable length 1,5 m.; in
casethesupplycordsetmustbereplaced,itshall
bereplacedwithanidenticalsethavingthesame
technical specs and followingcarefully the
instructionsanddiagramsbelow:
1) Disconnect appliance from electrical power
supplyreceptacle
2) Slideouttheappliancefrominstallationplace
toaccesstobackenclosure
panel
3) Remove back enclosure panel by removing
the6screwsasshownbelow.
4) Loosestrainreliefbyunscrewingthetwo
strainrelief'sscrewsasindiagram.