Install Guide

12
INSTALLINGTHEANTITIPStabilityDEVICE
Theantitipbracketshippedwiththerangemust
beproperly securedto the rearwallas shownin
thepicturebelow.
Theheightofthebracketfromthefloormustbe
determined after the range legs have been
adjusted to the desired height and
afterthe
rangehasbeenlevelled.
Measure the distance from the floor to the
bottom of the antitip bracket receptacle on the
backoftheappliance.
Position the two antitip brackets on the wall at
the desired height plus 1/8" (0.32 cm). The
bracketsmustbeplaced at
2”5/16(6,0cm)from
the side of the range. The distance between the
twobracketis43”1/4(109,8cm).
Secure thebrackets to thewall with appropriate
hardware.
Slidetherangeagainstthewalluntilthebrackets
are fully inserted into their receptacles on the
backoftherange.
INSTALLATIONREQUIREMENTS
ELECTRICAL
A properly grounded and horizontallymounted
electrical receptacle Type NEMA 1450R should
beinstallednohigherthan3"(7.6cm)abovethe
floor,nolessthan2”(5cm)andnomorethan8”
(20,3 cm) from the left side (facing product);
refer to ELE CTRICAL CONNECTION section pag.
13.
Checkalllocalcoderequirements.
GAS
Anagencyapproved,properlysizedmanualshut
off valve should be installed no higher than 3"
(7.6 cm) above the floor and no less than 2” (5
cm)andnomorethan8”(20.3cm)fromtheright
side(facingproduct).
To connect gas
between shutoff valve and
regulator, use agency approved, properly sized
flexible or rigid pipe. Check all local code
requirements.