Design Guide

53bertazzoni.com
SIDE VIEW
FRONT VIEW
TOP VIEW
Combustible material cannot be installed within shaded area.
18"
457
36"
915
13"
330
6"
152
36"
913
6 5/8"
168
25"
635
3 1/2"
90
36"
914
29 3/8"
746
36"
915
AREA FOR ELECTRIC
AND GAS CONNECTION
36” Rangetops
Installation
Combustible material cannot be located within shaded area.
GAS RANGETOPS & COOKTOPS