30” Gas Cooktop Front Control
Installation requirements
INSTALLATION
The gas cooktop can be mounted in a standard installation 
sitting on top of the countertop surface.
The clearance between the hob and the kitchen furniture 
or other installed appliances must be enough to ensure 
sufficient cooling air ventilation.
If a drawer is placed under the work, avoid to put into this 
drawer flammable objects or not heat-resistant objects.
For installation with an updraft or downdraft hood as well as 
any OTR, refer to the hood/OTR manufacturer’s installation 
requirements.
For instructions and clearance of product combinations 
please see the Multiple Installation Sections (page 86).
CABINET REQUIREMENT
To prevent possible damage to cabinets and cabinet finishes, 
the countertop must be able to withstand temperatures up to 
300°F (149°C). Installation of the appliance must be performed 
in accordance with the provisions of applicable legislation.
BE SURE that support for this appliance is horizontale before 
you perform the installation. The cabinet base must be flat and 
capable of supporting the weight of the oven when in use.
ELECTRICAL REQUIREMENT
The installation must comply with all applicable electrical codes.
A properly-grounded horizontally- mounted electrical receptacle 
should be installed. Place the electrical supply flush with the 
back wall and within the shaded area shown in the illustrations.
Placement within the opening may require additional cabinet 
depth.
EG
10"
254
10"
254
4"
102
COUNTERTOP
FRONT VIEW 
GAS CONNECTION
The gas cooktop can be used with Natural or LP/Propane 
gas. An agency-approved, properly-sized manual shutoff
valve should be installed. To connect gas between shut-off 
valve and regulator, use agency-approved, properly sized 
flexible or rigid pipe. Check all local code requirements.
Since service pressure may fluctuate with local demand, every 
gas cooktop must be equipped with the supplied pressure 
regulator on the incoming service line for safe and efficient 
operation.
Minimum Suggested Load on 
Cabinet Base Board
81lb (37kg)
Electrical supply 120 V 60 Hz 1 W
Service 1 Amp
Power Connection NEMA 5-15P plug with 59” cord
Gas Inlet 1/2” NPT
Natural Gas 4” iwc (1.00 kPa)
LPG Gas 10” iwc (2.50 kPa)
For detailed installation specifications consult the installation manual.