Installation Drawing

ELECTRICAL CONNECTION
The installation must be done through the use of a Junction Box.
Before making electrical connections to power supply,
the electrical box must be secured in place as indicated
3"
5
32
18"
29
32
48"
11"
7
32
min 26"
31
32
- max 44"
7
8
10"
1
32
PRODUCT DIMENSIONS
26"
31
32
18"
29
32
44"
7
8
SIDE VIEW
MIN INSTALLATION
MAX INSTALLATION
max 106"
13
16
for electric worktop - max 110"
13
16
for gas worktop
26"
- 30"
26"
31
32
44"
7
8
3"
5
32
48"
35"
15
16
min 88"
29
32
for electric worktop - min 92"
29
32
for gas worktop
PRODUCT INSTALLATION
Hood Clearance
Recommended height above cooking surface:
min 26"
for electric worktop
min 30"
for gas worktop
Power Supply Connection
For connection to the power supply refer to the follows:
BLACK = L line
WHITE = N neutral
GREEN/YELLOW = G ground
Wiring box cover
If the power cord to connect the hood to the main power comes from the wall in the grey area (8’’x17’’), it must
have a minimum lenght of 20’’ to be connected to the Junction Box.
17"
8"

Summary of content (1 pages)