This range  will best  perform when  installed with 
Bertazzoni  exhaust  hoods.  These  hoods  have 
been  designed  to  work  in  conjunction  with  the 
Bertazzoni range and have the same fi nish for a 
perfect look. 
Before installation of the exhaust hood, consult lo-
cal or regional building and installation codes for 
additional specifi c clearance requirements. 
Refer  to  the  range  hood  installation  instructions 
provided by the manufacturer for additional infor-
mation. 
Select Hood and Blower Models:
 • For wall installations, the hood should be equal 
or  larger  width  than  the  range.  Where  space 
permits, a hood larger than the range may be 
desirable for improved ventilation performance.
 • For island installations, the hood width should 
overhang  the  range  by  a  minimum  of  3”  (76 
mm) on each side.
Hood Placement:
 • For best removal of smoke and odors, the 
lower edge of the hood should be installed 
between 25 1/2” (65 cm) and 31 1/2” (80 cm) 
above the range cooking surface. 
 • If the hood contains any combustible materials 
(i.e. a wood covering), it must be installed at a 
minimum of 36” (914 mm) above the cooking 
surface.
Consider Make-Up Air:
Due to the high volume of ventilation air, a sour-
ce of outside replacement air is recommended. 
This is particularly important for tightly sealed 
and insulated homes. A qualifi ed heating and 
ventilating contractor should be consulted.
/ Ventilation preparation / Specifi cations
VENTILATION PREPARATION
SPECIFICATIONS
A
30’’ 36’’ 48’’
A
27''
/8
37''
1/2
 MAX
1''
15/16
25''
/16
2''
1''
5/8
32''
3''
3/4
 - 5'' 
1/2
5''
1''
 5/8
1''
1/8
''
/
23''
7/8
3''
7/16
3 '' 
11/16
2''
7/16
A