Installation Manual for Dual Fuel Ranges EN 1
14
/ Gas connection
Warning! 
DO  NOT  USE  AN  OPEN  FLAME  WHEN 
CHECKING FOR LEAKS! 
Leak testing of the appliance shall be conducted 
according to the manufacturer’s instructions. Be-
fore placing the oven into operation, always check 
for leaks with soapy water solution or other accep-
table method. 
Check for gas leakage with soapy water solution or 
other acceptable methods in all gas connections 
installed between inlet gas pipe of the appliance, 
gas regulator, till to the manual shut-off valve.
All gas connections must comply with national and 
local codes. The gas supply line (service) must be 
the same size or greater than the inlet line of the 
appliance. This range uses a 1/2” NPT inlet (see 
drawing below for details of gas connection). On 
all pipe joints use appropriate sealant resistant to 
gas to joint the adapter to range manifold use only 
the blue gasket supplied.
If necessary, the appliance must be converted by 
the dealer, by a factory-trained professional or by 
a qualifi ed licensed plumber or gas service com-
pany. 
Gas conversion is important for safe and eff ecti-
ve use of the appliance. It is the responsibility of 
the dealer and the owner of the range to perform 
the  appropriate  gas  conversion  following  the  di-
rections of the manufacturer. 
THE  GAS  CONVERSION  PROCEDURE  IS 
DESCRIBED  IN  THIS  MANUAL  AND  IN  THE 
PACKAGE  CONTAINING  THE  CONVERSION 
NOZZLES SHIPPED WITH EVERY RANGE.
Please provide  the service  person with  this ma-
nual before work is started on the range.
MANUAL SHUT-OFF VALVE 
THIS  VALVE  IS  NOT SHIPPED  WITH THE AP-
PLIANC AND MUST BE SUPPLIED BY THE IN-
STALLER. 
The manual shut-off valve must be installed in the 
gas service line between the gas hook-up on the 
wall and the appliance inlet, in a position where it 
can be reached quickly in the event of an emer-
gency.
In  Massachusetts:  A  ‘T’  handle  type  manual 
gas valve must be installed in the gas supply line 
to this appliance.
FLEXIBLE CONNECTIONS
In case of installation with fl exible couplings and/
or quick-disconnect fi ttings, the installer must use 
a  heavy-duty,  AGA  design-certifi ed  commercial 
fl exible connector of at least 1/2” (1.3 cm) ID NPT 
(with  suitable  strain  reliefs)  in  compliance  with 
ANSI Z21.41 and Z21.69 standards.
In Massachusetts: The unit must be installed 
with a 36” (3-foot) long fl exible gas connector.
In Canada:  use  CAN  1-6.10-88  metal  connec-
tors for gas appliances and CAN 1-6.9 M79 quick 
disconnect device for use with gas fuel.
PRESSURE TEST-POINT STOPPER 
VALVE
To avoid gas leaks, the pressure test-point stop-
per valve and gasket supplied with the range must 
be installed on  the gas fi tting at  the back of  the 
range according to the diagram below.
GAS CONNECTION
GAS PIPE
GASKET
PRESSURE TEST-POINT 
STOPPER
GAS CONNECTION ADAPTOR 
1/2’’NPT WITH PRESSURE TEST 
POINT 1/8’’ NPT (TO BE FIXED 
TOWARD EXTERNAL SIDE OF 
THE APPLIANCE)