CONNECTION TO MONO-PHASE ELECTRICITY
Ovens equipped with tri-polar power supply cables are constructed to function with alternating current, and
with the voltage and frequency indicated on the technical label on the appliance.
Assembly of the power cable:
1. Open the terminal board by placing a screwdriver under the side flaps on the cover, pull and then open the
cover (see the figure).
2. Install the power supply cable, unscrew the screws on the cablegrip and the three screws on contacts L-N-
and then attach the wires under the screw heads respecting the colours Blue (N), Brown (L), Green
Yellow (see the figure).
3. Attach the cable to the appropriate cable holder.
4. Close the terminal board cover.
Attaching the power supply cable to the mains.
For direct connection to the mains power, it is necessary to use a device that ensures that the mains power
is disconnected, with a distance between contacts that allows complete disconnection in compliance with
surge category III and installation regulations. Assemble a standard plug for the capacity indicated on the
features typeplate. If the oven has a direct connection to the mains electricity supply, it is necessary to install
an omnipolar switch between the appliance and mains power with a minimum opening between the contacts
of 3 mm dimensioned for the indicated capacity and in compliance with currently enforced regulations (the
switch must not interrupt the ground cable). The power supply cable must be positioned in such a way that it
does not exceed the room temperature by 50°C at any point. The installer is responsible for correctly
hooking-up the electricity connection and adherence to safety regulations
Before hooking-up to the mains supply, make sure that: -the socket has a ground connection and complies
with legal regulations;
-the socket is able to withstand the oven's maximum power capacity indicated on the features typeplate (see
below);
- The power supply voltage is within the values listed in the electrical characteristics label (see below);
- the socket is compatible with the appliance plug.
- If this is not the case, replace the socket or the plug. Do not use extension cords or multiple sockets.
- Once the appliance is installed, the electrical cable and the electrical power socket must be easy to reach.
- The cable must not be bent or compressed.
- The cable must be periodically checked and only replaced by authorized technicians.
- The Company declines all responsibility if these instructions are not adhered to.
Voltage and power supply frequency:
220-240 V~ 50/60 Hz
Replacement of the power cable:
If the power cable needs to be replaced, use cables of the following type only:
- H05 RR-F,
- H05 V2V2-F (T90),
- H05 VV-F,
suitable for the operating capacity and temperature. The green-yellow ground cable must be longer than the
other two conductors by approximately 2cm