Instruction manual

10
INSTALLATION
Important: any adjustments, maintenance, etc. must be executed with the oven disconnected from
electricity. To guarantee proper operation of the built-in appliance, the furniture unit must have suitable
characteristics:
-the panels adjacent to the oven must be constructed in heat resistant materials;
-in the case of veneered wood furniture units, the glue must be heat resistant to temperatures up to 100°C;
Before installing the oven into the furniture, it is necessary to assemble the lower profile “drip-catcher”
(included in the packaging). This “drip-catcher” must be attached to the lower part using the 3 screws
supplied (please see the next figure).
The oven must be located in a standard opening of 600mm, as illustrated in Fig. 1, whether under a counter
or in a column position.
When inserting the oven into a column it is indispensable to ensure adequate ventilation by installing
openings as illustrated in the figure.
The oven is secured to the furniture unit by four “A” screws located in the holes of the frame. Make sure not
to lift the oven by its door when inserting it; furthermore, do not place excessive pressure on the door when it
is open.
Note: if no opening has been anticipated in the upper part of the column furniture, make a hole which is
560mm wide and 40-50mm high in the lower part of the column