Cut Sheet
Ceiling Fans to be furnished as specified, Leading Edge.
Fans to be U.L. listed Standard 507 (model 56007 is
cULus listed) with matching U.L. listed solid state controls.
All motors to be direct-drive
permanent split capacitor type, with permanently sealed
ball bearings. All motors to have built in, self-resetting
(internal) thermal overload protector TI9700.
All fans to have factory installed Secondary Support
Cable Assembly connected to motor shaft, with minimum
6 feet galvanized cable
1
/
8
” 7x7 with rated breaking
strength of 1700 lbs. and must comply with CSA std.
C22.2
Sept. 1986.
Fan blades to be straight with contoured shaped design
for maximum efficiency. Note: Fans shall not be installed
with blade height less than 10’ from floor.
Fans used with motor speed controls must be labeled in
accordance with U.L. 507 “Suitable for use with solid state
motor speed controls”.
Factory supplied accessories to include:
A) Solid state motor speed controls (U.L. listed)
B) Special length downrods
C) Totally enclosed impact resistant fan guard
D) Tilted canopy cover
E) Outdoor location installation kit
ITEM
QTY.
MARK
MODEL
NUMBER
BLADE
SWEEP
CFM
AREA
COVERAGE
RPM
AMPS
ACCESSORIES
REMARKS
NOTE: All measurements are calculated
from ceiling or beam line with “J” hook
mounted securely in center of 1
1
/
2
” deep
conduit box and downrod supplied on
rubber roller (See illustration).
VOLTS
SCHEDULE
PROJECT
DATE
SHEET OF
ENGINEER
ARCHITECT
CONTRACTOR
SUBMITTED BY
CEILING FAN DIMENSIONS* (mm)
MODELS SUPPLIED WITH
24” DOWNROD
MODEL SERIES
A
D
C
B
56001**, 56011,
56007, 56002
60001, 60002,
60011
56”
60”
33
1
/
2
”
34”
19”
19”
30
1
/
2
”
30
3
/
4
”
* Allow for 1/2” variance in “J” hook depth.
** Identical measurements for 220 volt and 277 volt models.
®
Heavy Duty High Performance Industrial Ceiling Fans
Commercial Ceiling Fans
SUBMITTAL SHEET