Third Party Verification Claim

QUALITY FILTER TESTING LABORATORY, LLC
41 D Germay Drive Wilmington DE 19804
PHONE 856-583-0445 www.enviroteklab.com
EPA ID # NJ01298 NJ DEP ID # DE009 IAPMO ID #102
Report #18-38-Berkey with post filter
Page 1 of 1
FILTER WATER TEST REPORT
Report # 18-38 (Berkey With Post Filter)
Report Date: 02/18/2018
Customer Name: New Millennium Concepts, Ltd.
Product: Berkey Gravity Filter with post filter
Volume Tested: 100 gallons
Flushing Volume: 1 gallon
Test Description: Std. 53 – Fluoride
Performance Standard: 53 – 2015
Fluoride P/F: Passed
Pass/Fail Criteria (Fluoride): 81.3% Reduction
Table 1. Fluoride Test
Accumulated
Volume
Influent Water Fluoride
Concentration in mg/L
Influent
Water pH
TDS in
mg/L
Effluent Fluoride
Concentration in mg/L
Fluoride %
Reduction
Start 3.82 6.46 327 0.10 97.4
5 gallons 3.82 6.46 327 0.06 98.4
25 gallons 3.75 6.48 320 0.07 98.1
50 gallons 3.79 6.52 318 0.07 98.2
75 gallons 3.80 6.51 310 0.07 98.2
100 gallons 3.80 6.52 312 0.11 97.1
CERTIFICATION OF RESULTS:
I certify in writing that all analyses, and reporting performed herein, comply with all requirements set forth in
N.J.A.C. 7:9E and N.J.A.C. 7:18, and hereby certify that this laboratory is in compliance with all laboratory
certification and quality control procedures and requirements as set forth in N.J.A.C. 7:18; the NYCRR Subpart
55-2, the National Environmental Laboratory Accreditation Conference (NELAC) Institute Standards, and the
ISO 17025.
Disclaimer: The test results are only related to the filter cartridges tested, in the condition received at the
laboratory.