Technical information
43
RADIO CONTROL UNIT 1–10 V RMD
Function
■
Switching and dimming of electronic ballasts or transformers with
1–10 V interface in combination with the radio receiver RMD
■
Switching on to switch-on brightness for 1 min. when a radio motion
detector telegram is received
■
ON/OFF switching via button on the device (construction site function)
Special product features
■
The switch-on brightness can be saved
■
Possible to delete all of the taught-in transmitters (factory setting)
Technical data
Rated voltage: 230 V
~, 50/60 Hz
Control voltage: 1–10 V
Control current: max. 15 mA
Electrical isolation 1–10 V: 2 kV basic insulation
Switching contact: relay contact
Connected load
- ohmic load: max. 1800 W
- electronic ballast, transformers: type-dependent
Upstream circuit breaker: 10 A
Operating temperature: 0 to +45 °C
Protection class: IP 20
Dimensions/width: 72 mm, 4 modules
Order no.: 9465 01 00
RADIO SHUTTER ACTUATOR RMD
Function
■
Controlling a shutter or blind motor in combination with the radio
receiver RMD
■
Moving of hangings via button on the device (construction site function)
Special product features
■
Master control is easy to implement by teaching-in a master trans-
mitter with multiple shutter actuators
■
End positions (completely open, completely closed) can be integrated
into light scenes
Technical data
Rated voltage: AC 230 V
~, 50/60 Hz
Circuit breaker: 10 A
Breaking capacity: max. 1 motor 700 W
Relay output: 2 normally open contacts
(non-floating and interlocked
with each other)
Switching time for change of direction: approx. 1 sec.
Continuous operation: approx. 2 min.
Teachable radio transmitters: max. 14
Operating temperature: 0 to +45 °C
Protection class: IP 20
Dimensions/width: 36 mm, 2 modules
Order no.: 9460 01 00
N
L
N
L
N
L
c
d
e
f
L LN
L N
1 1
Radio control unit 1–10 V RMD Radio shutter actuator RMD with motor