Technical information

37
Radio push-button interface
flush-mounted
0126
RADIO PUSH-BUTTON INTERFACE FLUSH-MOUNTED
4GANG
Function
■
Detection of the switching states of potential free switches/contacts
and push-buttons at the 4 inputs
■
Conversion to radio telegrams that are evaluated by all radio receivers
■
Selection of 8 different operating modes via 5gang microswitch
Special product features
■
Suitable for Berker special ranges such as Berker TS, Glasserie
■
Installation in flush-mounted box behind flush-mounted insert possible
Operating modes
■
Single-surface switching and dimming with up to 4 push-buttons:
One channel per input, pressing once results in switching (toggling)
of the telegram type (ON/OFF, BRIGHTER/DARKER) in the radio
push-button interface
■
2-surface switching, dimming and moving shutters with push-buttons:
Inputs E1/E2 and E3/E4 each form one channel
■
Switching with switches (normally open contacts):
The inputs E1 to E4 each form one channel for activating radio
receivers. When the switch contact is closed switch-on telegrams are
sent, when the switch contact is open switch-off telegrams are sent
■
Switching with switches (normally closed contacts):
The inputs E1 to E4 each form one channel for activating radio recei-
vers. When the switch contact is closed switch-off telegrams are
sent, when the switch contact is open switch-on telegrams are sent
■
Master ON, master OFF, light scenes 1 and 2 (with push-buttons):
E1: Switch ON all taught-in receivers
E2: Switch OFF all taught-in receivers
E3: Retrieve or save light scene 1
E4: Retrieve or save light scene 2
■
Master OFF, light scenes 1 to 3 (with push-buttons):
E1: Switch OFF all taught-in receivers
E2: Retrieve or save light scene 1
E3: Retrieve or save light scene 2
E4: Retrieve or save light scene 3
■
Master OFF, light scenes 3 to 5 (with push-buttons):
E1: Switch OFF all taught-in receivers
E2: Retrieve or save light scene 3
E3: Retrieve or save light scene 4
E4: Retrieve or save light scene 5
■
Light scenes 1 to 4 (with push-buttons)
E1 to E4: Retrieve or save light scenes 1 to 4
Technical data
Power supply: 3 V =
Battery: 1 x lithium coin cell CR 2032
Battery empty indication: repeated quick flashing of the LEDs
on the device when transmitting
Length of connecting cables: approx. 290 mm,
extendable up to 5 m
Protection class: IP 20
Operating temperature: -20 to +55 °C
Dimensions (L x W x H): 45 x 40 x 10 mm
Order no.: 0126
Connection diagram radio push-button interface flush-mounted in conjunction with
Berker TS
/Berker TS Sensor