Technical information

36
RADIO TRANSMITTER FLUSH-MOUNTED WITH
PHASE-CONDUCTOR
Function
■
When the inputs (E1, E2) are activated with mains voltage (230 V ~)
radio telegrams are sent that are evaluated by all radio receivers
■
4 operating modes for activating switch, dimmer and shutter actuators,
selection of the operating modes via button, display by LED on the device
Special product features
■
Installation in deep flush-mounted box behind flush-mounted insert
possible
Operating modes
■
2-channel dimming, toggle (E1 and E2) for independent control
of 2 radio dim actuators. Connection of conventional push-buttons
(normally open contacts): Pressing the push-button results in switch-
ing (toggling) of the telegram type in the transmitter
- press briefly (< 1s): ON
/OFF switching
- press longer (
1 s): BRIGHTER/DARKER dimming
■
2-channel switching (E1 and E2) for independent control of 2 radio
switch actuators.
- Connection of conventional switches (
normally open contacts):
closing:
switch-on telegram is sent
opening: switch-off telegram is sent
■
1-channel dimming (E1/E2) for activating a radio dim actuator.
- Connection of two conventional push-buttons (normally open
contacts), pressing from:
T1 < 1 s: ON
T1
1 s: BRIGHTER dimming
T2 < 1 s: OFF
T2
1 s: DARKER dimming
■
1-channel shutter (E1/E2) for activating a radio shutter actuator.
- Connection of a shutter switch or a RolloTec
®
insert
(see illustration below):
When switch J1 or the contacts in the RolloTec
®
insert close, a
telegram is sent to move the shutter up or down; when opened
the shutter is stopped
Technical data
Power supply: 230 V ~, 50/60 Hz
Number of channels: 12 (depending on operating
mode)
Cable length: approx. 210 mm, prefabricate
Operating temperature: -20 to +55 °C
Protection class: IP 20
Dimensions (Ø x H): 52 x 23 mm
Order no.:
0124 10
L
N
ON/OFF
Prog.
L
L
Connection diagram with RolloTec
®
insert Operating mode 1-channel shutter
FACTS YOU SHOULD KNOW