Specifications
Troubleshooting
Electrical Failure
1. Isthepilotlightilluminated?Ifnot:
• Isthepowercordcompletelypluggedintothewalloutlet?
• Checkthepowercordforcutsorbreaks.
• Areyougettingelectricityfromthewalloutlet?Checkbyplugginginanotherpieceofequipment
withthesameelectricalrequirements.
2. Isthepilotlightilluminatedbutblinking?Ifso,thenpushthestopbuttonandthenthestartbutton.Ifthe
lightisstillblinking,
thencontactyournearestHobartServicelocationorDesignatedBerkelService
location.IfyoudonotknowyournearestHobartServicelocationoryournearestDesignatedBerkel
ServiceLocation,thenseepage10fordetailsonwhomtocontact.
3. Ifthecorrectionofanyoftheaboveconditionsdoesnotresultinafunctionalslicer,callHobartServiceor
yourDesignatedBerkelServiceLocation.
Can't remove product table
1. Makesurethegaugeplateisclosedbyturningthethicknesscontrolknobto0,andtheproducttableis
fullytothefrontoftheslicer.
Product table doesn’t move freely
1. Checktomakesuretheslicerisnotintheautomaticmode.
Note: The mechanism in the undercarriage should not be oiled or greased.
Pusher is not sliding easily on the rod
1. CheckthattherodiscleanandapplyBerkeloiltotherod.
Thickness Control Knob not Advancing Gauge Plate
1. Istheproducttableproperlyattachedtothesupportarm?Ifnot,thenthegaugeplatecannotbeopened.
2. Ifthecorrectionoftheaboveconditiondoesnotresultinafunctionalslicer,
then contact your nearest
HobartServicelocationorDesignatedBerkelServicelocation.
Knife not sharpening
1. Aresharpeningproceduresbeingfollowedexactlyasshowninthismanual?
2. Aresharpeningstonesclean?Ifnot,thenremovethemfromtheassemblyandcleanthemthoroughlywith
waterandastiffbristledbrush.Theyarelefthandthreadednuts.
3. Aresharpeningstoneswornandnotmakingcontactwiththeknife?Ifso,thenreplacethem.
4. Istheknifeclean?Ifcoatedwithfoodfats,thesharpeningstoneswon’tsharpentheknife.Cleantheknife
andstones.
X13-PLUS & X13A-PLUS owner/operaTor manUal • 11