Technical data
• Install new switch. Make sure that OFF position is toward the front.
• Re-install the switch boot and position switch up through lower housing.
• Re-install 4 bolts and wiring.
D. MICRO-SWITCH ADJUSTMENT (4175-0020) The plastic tenderizer neck is fitted with a magnet that
interlocks with the magnet on the micro-switch located inside the right side of the machine case.
The micro-switch is mounted in slotted holes for adjustment. If the magnet has been removed, re-install the
magnet with the RED dot facing the RED dot on the neck magnet.
With the neck raised, the micro-switch magnet should rest against the inside wall of the lower housing. When
the neck is lowered into operating position, the inner magnet should be repelled and activate the microswitch.
Adjust the micro-switch by loosening the nuts on the mounting bolts and position the magnet exactly oppo-
site the magnet on the neck.
When you tighten the nuts after adjusting, seal them with a drop of silicone sealer.
S6151-DL-MMM-010
1-18










