Technical data

1. Disassembling Tenderizer Blade Assembly
a. Mount shaft upright in bench vice at the clutch end.
b. Remove complete screw assembly bearing.
c. Remove blades (3275-0014) and round hole spacer (3375-0164 (1)) and square hole spacers (3375-0165
(41)) down through blade(s) to be replaced. Note direction of the notch of the last blade removed.
2. Reassembling Tenderizer Blade Assembly
Blades are placed on shaft staggered at 180 degrees. They are notched for easy identification and replace-
ment. Front blades are mounted with blade incline forward and rear blades are mounted with blade incline fac-
ing the rear. Incline of blade always matches incline of gear teeth.
NOTE
If not mounted in 180 degree rotation and in proper direction, the blades will
hang up rather than mesh and damage either the blades or the entire assembly.
a. Reassemble blades and spacers installing blade first, then spacers alternately. (See pictures on pages 7 and
9, drawing, page 26.
b. The last blade on the Assembly does NOT FIT on the shaft, but is located on the shoulder of the screw.
The last blade MUST be located on this shoulder.
The solid spacer (3375-0164), the only one with a round hole, must be centered as the screw assembly on
either front or rear shaft is replaced so that it is aligned with the rest of the spacers.
S6151-DL-MMM-010
1-8