Owners manual
INSTALLATION:
Battery cables must be correctly selected for the maximum loads expected.
Cables must be a minimum of 1x 95mm² (3/0) to achieve 350 amps continuous.
Cables must be a minimum of 2x 95mm² (2x 3/0) to achieve 500 amps continuous.
Ensure nuts on studs are correctly tightened. Recommended torque is 18 Nm
(13.3 lbf). Maximum torque 25 Nm (18.5 lbf).
Any momentary on/off remote switch can be used to activate the 720-MDVSO.
When rst connected to a battery, the VSS will go through a power up sequence which takes approximately 30 seconds to complete.
This will be accompanied by rapid ashes on the LED, during which the VSS will detect whether it is part of a 12 volt, or 24 volt
system. This may also occur if a 12 volt system reaches and sustains voltage above 16.0V. In this situation, if in the “Auto On”
position, the VSS will immediate switch to “Auto Off”, and with the voltage >16V, the VSS will change into 24 volt system mode. If
voltage is not sustained above 16V, the VSS will return to 12V mode.
WIRES FOR CONNECTION:
Red • Optional LED Wire
Green • Optional From Remote Switch
Black • Supply Negative
Input Stud • High Current Connection From Battery 1
Ouput Stud • High Current Connection From Battery 2
Terminated into Wago plug
}
Motorised Battery Switch
Model: 720-MDVSO 12/24V Voltage Sensitive Switch
OPERATION AND INSTALLATION INSTRUCTIONS