Owners manual

INSTALLATION:
Battery cables must be correctly selected for the maximum loads expected.
Cables must be a minimum of 1x 95mm² (3/0) to achieve 350 amps continuous.
Cables must be a minimum of 2x 95mm² (2x 3/0) to achieve 500 amps continuous.
Ensure nuts on studs are correctly tightened. Recommended torque is 18 Nm
(13.3 lbf). Maximum torque 25 Nm (18.5 lbf).
Any momentary on/off remote switch can be used to activate the 720-MDVSO.
When rst connected to a battery, the VSS will go through a power up sequence which takes approximately 30 seconds to complete.
This will be accompanied by rapid ashes on the LED, during which the VSS will detect whether it is part of a 12 volt, or 24 volt
system. This may also occur if a 12 volt system reaches and sustains voltage above 16.0V. In this situation, if in the “Auto On”
position, the VSS will immediate switch to “Auto Off”, and with the voltage >16V, the VSS will change into 24 volt system mode. If
voltage is not sustained above 16V, the VSS will return to 12V mode.
WIRES FOR CONNECTION:
Red • Optional LED Wire
Green • Optional From Remote Switch
Black • Supply Negative
Input Stud • High Current Connection From Battery 1
Ouput Stud • High Current Connection From Battery 2
Terminated into Wago plug
}
Motorised Battery Switch
Model: 720-MDVSO 12/24V Voltage Sensitive Switch
OPERATION AND INSTALLATION INSTRUCTIONS