Owners manual

Motorised Battery Switch
Model: 720-MDVSO 12/24V Voltage Sensitive Switch
OPERATION AND INSTALLATION INSTRUCTIONS
SPECIFICATIONS:
• Continuous rating: 500 Amps DC -minimum 2x95mm² (2x 3/0) cables
• Intermittent rating: 700 Amps DC -minimum 2x95mm² (2x 3/0) cables
• Cranking rating: 2500 Amps DC -minimum 2x95mm² (2x 3/0) cables
• Maximum Voltage: 32 Volts DC (12V or 24V systems)
Voltage Note: Both battery banks must be the same voltage, either 12V or 24V
• Operating Voltage: 8 to 30.5 Volts DC
VSS Engages: 13.3V (26.6V)
VSS Disengages: 12.7V (25.4V)
• Sensing: Senses voltage on both battery banks
• Operation: Manual On/Off, Auto On/Off
• Mounting: Recessed or surface
• Ignition protected Meets UL 1107 standards
• IP Rating IP65
• Stud Size: 2 x 12mm (1/2”) –See Installation section for torques
• Materials: Tinned copper conductors/studs, stainless steel nuts,
high temperature bre reinforced plastics
• Power draw: Off/Auto Off: 5mA @12V, 5.5mA @24V
Auto On/On: 8.3mA @12V, 12.5mA @24V
• Emergency Parallel: Remote switch activates parallel for 10 minute period
Pressing remote switch for 6 seconds, deactivates
parallel function.
Remote emergency parallel VSS control is achieved by using a remotely
mounted momentary switch, such as the BEP #80-724-0007-00 unit (pictured
at right), which also features an LED to show the VSS status. When operated,
the remote switch engages the 720-MDVSO contacts, paralleling the batteries,
for a 10 minute period, for example to get an engine started following a at start
battery.
Alternatively, the VSS can be manually overridden to either “Manual On”,
or “Manual Off” modes.