Update Sensor Firmware Using Honeywell Gateway
Before you upgrade the device firmware, obtain the correct device descriptor (DD)file required
for each type of Ranger Pro device from Bently Nevada technical support. You only need to add a
DDfile to the gateway once for each device type.
To update the DDfile on a Honeywell gateway, see Provision Using the Honeywell ISA100 Gateway.
To update firmware using a Honeywell OneWireless Device Manager:
1. Verify that all Ranger Pro devices are provisioned, connected to the network, and joined to
the gateway.
2. Open Honeywell OneWireless Device Manager (WDM).
3. In the Selection Panel, select the device you want to upgrade.
4. In the tools ribbon, click Upgrade and select Application. The Application Firmware
Upgrade dialog box is displayed.
5. To add a firmware file, click Add. The Windows Open dialog box is displayed.
6. Navigate to the location of the firmware file. Select it and click Open. The firmware is listed in
Available Firmware Files.
7. Select the Ranger Pro device to be updated and click Upgrade. The firmware update is
automatically applied.
8. Refresh the list of Ranger Pro devices.
a. Delete the upgraded device(s) from Honeywell WDM.
b. Allow the device to rejoin.
9. Once loaded, Honeywell applies the correct device descriptor (DD)file to each device.
53/57