User's Guide
Table Of Contents
Measurement
Type
Default Mode
Measurement
Units
Default Sub-
units
(RMS or Peak)
Default F
min
(high pass
filter
frequency)
Default F
max
(low pass
filter
frequency)
Temperature Enabled °F, °C N/A N/A N/A
Acceleration
Overall
Enabled g, m/s^2 RMS X:5
Y: 5
Z: 5
X: 5000
Y: 5000
Z: 10000
Velocity Overall Enabled mm/s, inches/s RMS X:5
Y: 5
Z: 5
X: 1000
Y: 1000
Z: 1000
PeakDemod
Overall
Enabled N/A Peak N/A N/A
Dynamic Data
Dynamic data is measured at the interval and start date/time set by the user. You can select the
number of samples, F
min
, F
max
, and time interval. Dynamic data is collected sequentially for each
measurement axis and time stamped when the data collection occurs.
Measurement
Type
Default Mode
Measurement
Units
Default Fmin
(high pass
filter
frequency)
Default Fmax
(low pass
filter
frequency )
Other
Acceleration
Waveforms
Enabled g, m/s^2 N/A N/A Measurement
samples used:
4096
Velocity
Spectrum (rms
only sub-units)
Enabled mm/s, inches/s X:5
Y: 5
Z: 5
X: 1000
Y: 1000
Z: 1000
Lines Default
FFTPoints:
1600
PeakDemod
Spectrum (Peak
only sub-units)
Enabled
(Z axis only)
g, m/s^2 X:5
Y: 5
Z: 5
1000
Lines Default
FFTPoints:
1600
40/57
Ranger Pro Wireless Condition Monitoring Device
User Guide 125M6113 Rev. F