User's Guide

Measurement
Type
Default Mode
Measurement
Units
Default Sub-
units
(RMS or Peak)
Default F
min
(high pass
filter
frequency)
Default F
max
(low pass
filter
frequency)
Temperature Enabled °F, °C N/A N/A N/A
Acceleration
Overall
Enabled g, m/s^2 RMS X:5
Y: 5
Z: 5
X: 5000
Y: 5000
Z: 10000
Velocity Overall Enabled mm/s, inches/s RMS X:5
Y: 5
Z: 5
X: 1000
Y: 1000
Z: 1000
PeakDemod
Overall
Enabled N/A Peak N/A N/A
Dynamic Data
Dynamic data is measured at the interval and start date/time set by the user. You can select the
number of samples, F
min
, F
max
, and time interval. Dynamic data is collected sequentially for each
measurement axis and time stamped when the data collection occurs.
Measurement
Type
Default Mode
Measurement
Units
Default Fmin
(high pass
filter
frequency)
Default Fmax
(low pass
filter
frequency )
Other
Acceleration
Waveforms
Enabled g, m/s^2 N/A N/A Measurement
samples used:
4096
Velocity
Spectrum (rms
only sub-units)
Enabled mm/s, inches/s X:5
Y: 5
Z: 5
X: 1000
Y: 1000
Z: 1000
Lines Default
FFTPoints:
1600
PeakDemod
Spectrum (Peak
only sub-units)
Enabled
(Z axis only)
g, m/s^2 X:5
Y: 5
Z: 5
1000
Lines Default
FFTPoints:
1600
40/57
Ranger Pro Wireless Condition Monitoring Device
User Guide 125M6113 Rev. F