Technical information

GAS CONVERSION
The heaters are supplied ready for use with (G20) Natural Gas as per the table below Conversion kits are available from
the manufacturer:
Natural Gas (G20)
TYPE 1 23456 7
Number of injectors 1 1 1 1 2 2 4
Diameter of injectors 3,10 410 480 555 500 540 450 mm/100
Gas supply pressure 20 mBar
Head pressure high fire 11,0 13,0 13,0 13,0 10,0 13,0 10,5 mBar
Head pressure low fire 6,0 7,0 6,5 6,5 7,0 6,5 5,0 mBar
BEFORE CHANGING INJECTORS ENSURE GAS SUPPLY IS ISOLATED
INSTRUCTIONS FOR CONVERSION TO PROPANE GAS G(31)
1. Change the injectors
2. Adjust the gas inlet pressure
3. Adjust the head pressure
4. Fit primary air diaphragm (if required )
5. Fit adhesive label supplied with kit indicating gas type
6. Ensure settings are correct as per the manual and data plate
CHANGE INJECTORS:
To change injectors:
Unscrew the natural gas injectors and replace them with the correct size injectors for propane as shown in table below:
Propane gas (G31)
TYPE 1 23456 7
Number of injectors 1 1 1 1 2 2 4
Diameter of injectors 190 250 280 335 285 320 255 mm/100
Replacing injectors single manifold (type 1-2-3-4-6)
Replacing injectors 2 per manifold (type 5-7)
Check the size stamped on the side of the
injector is correct to the data in the manual.
Ensure that the new injectors are correctly fitted
in the manifold and are gas tight, When the
conversion is complete fix the transfer supplied
with the kit showing the correct gas pressure on
to the manifold
Test for gas soundness on completion
Ensure that the aluminium washers supplied for
(types 5–7) are fitted when changing the
injectors.