Technical information
L1
Ø100
MAX 500
*
MIN. 400
C
12
:Installation showing both horizontal concentric flue discharge, and horizontal
independent pipe kit.
✴
100 mm type 1 – 2 – 3 – 4
150 mm type 5 – 6 – 7
MAX 320
L2
Ø100
*
MAXIMUM FLUE LENGTHS:
INDEPENDENT PIPE KIT HORIZONTAL CONCENTRIC FLUE
TYPE UNIT
L1 MIN. L1 MAX. L2 MIN. L2 MAX.
1
m 1,00 2,50 1,50 2,50
2
m 1,00 2,50 1,50 2,50
3
m 1,00 2,50 1,50 2,50
4
m 1,00 2,50 1,50 2,50
5
m 1,00 2,50 1,50 2,50
6
m 1,00 2,50 1,50 2,50
7
m 1,00 2,50 1,50 2,50
Only flue components and accessories supplied by the manufacturer should be used on installation.
In installations where condensation in the flue pipes is likely to be a problem consideration should be made for the
fitting of drain to the flue installation .
Each bend corresponds to about 0,8-1 meters of straight pipework.
Provision should be made for adequate ventilation .
25