Technical information
Table Of Contents

3 – KEYPAD OPERATION
LED Keypad and Display
16
3.1 Introduction
The MX provides a comprehensive set of parameters to allow the use of the reduced voltage solid state starter in nearly any industrial
application. While the starter can meet the requirements of many applications right out of the box, customization of parameter values
to better suit your particular application is easily accomplished with the standard, on-board, 4-digit, 7-segment LED display/keypad.
Optionally, a 2x16 character, back-lit LCD display/keypad may be added. This optional keypad may be mounted remotely from the
MX control card. The remote LCD keypad has the same keys as the standard display with several additional keys including start and
stop keys for operation of the starter from the keypad. When the remote LCD keypad is connected, the local display is disabled.
3.2 Standard Keypad and Display
The LED display provides information on starter operation and programming. The 4-digit, 7-segment display shows starter meter
outputs and programming data. Special symbols provide further information about the starter operation (see the following section).
Figure 7 – Standard Keypad and Display
PARAM DOWN UP ENTER
RESET
3.2.1 Viewing and Changing Parameters for the Standard Keypad
3.2.1.1 Viewing Parameter Values
Parameter view mode can be entered by:
1. At the default meter display, press the PARAM key to enter parameter mode. “P 1” is displayed to indicate Parameter 1.
2. Use the UP and DOWN keys to scroll through the available parameters.
3. Pressing the UP key from “P 1” advances to parameter “P 2”.
4. Pressing the DOWN key from “P 1” wraps around to the highest parameter.
5. The value of the parameter can be viewed by pressing the ENTER key.
6. To view another parameter without changing/saving the parameter, press the PARAM key to return to the parameter number
display.
To return to the default meter display either:
1. Press the PARAM key while in the parameter number display mode.
2. Wait 60 seconds and the display returns to the default meter display.