Technical information
Table Of Contents

10 – APPENDIX
152
Modbus Registers
Absolute Register
Address
Description R/W Range Units
30032/40032 Residual Ground Fault
Current
R %FLA
30033/40033 Average Voltage R Vrms
30034/40034 L1-L2 Voltage R Vrms
30035/40035 L2-L3 Voltage R Vrms
30036/40036 L3-L1 Voltage R Vrms
30037/40037 Motor Overload R %
30038/40038 Power Factor R -99 – +100
(in 16-bit two’s compliment signed format)
0.01
30039/40039 Watts (lower 16 Bits) R
30040/40040 Watts (upper16 Bits) R
(in 32 bit unsigned integer format) W
30041/40041 VA (lower 16 Bits) R
30042/40042 VA (upper 16 Bits) R
(in 32 bit unsigned integer format) VA
30043/40043 VARS (lower 16 Bits) R
30044/40044 VARS (upper 16 Bits) R
(in 32 bit two’s compliment signed interger
format)
var
30045/40045 kW hour (lower 16 Bits) R 0 – 999
30046/40046 KW hours (upper 16 Bits) R
kWh
30047/40047 Phase Order R 0: no line
1: ABC
2: CBA
3: SPH
-
30048/40048 Line Frequency R 230 – 720,
or 0 if no line
0.1 Hz
30049/40049 Analog Input R -1000 – +1000
(in 16-bit two’s compliment signed format)
0.1 %
30050/40050 Analog Output R 0 – 1000 0.1%
30051/40051 Running Time R 0 – 65535 Hours
30052/40052 Running Time R 0 – 59 Minutes
30053/40053 Starts R 0 – 65535 -
30054/40054 TruTorque % R %
30055/40055 Power % R %
30101/40101 Motor FLA R/W 1 – 6400 Arms
30102/40102 Rated Power Factor R/W 100 – 199 0.01
30103/40103 Independent
Starting/Running
Overload
R/W 0: Disabled
1: Enabled
-
30104/40104 Motor Running Overload
Enable
R/W 0: Disabled
1: Enabled
-
30105/40105 Motor Running Overload
Class
R/W 1 – 40 -
30106/40106 Motor Starting Overload
Enable
R/W 0: Disabled
1: Enabled
-
30107/40107 Motor Starting Overload
Class
R/W 1 – 40 -
30108/40108 Motor Overload Hot/Cold
Ratio
R/W 0 – 99 %
30109/40109 Motor Overload Cooling
Time
R/W 1 – 9999 0.1 Min
30110/40110 Local Source R/W 0: Keypad
1: Terminal
2: Serial
-
30111/40111 Remote Source R/W 0: Keypad
1: Terminal
2: Serial
-
30112/40112 Start Mode R/W 0: Open Loop Voltage Ramp
1: Closed Loop Current Ramp
2: TruTorque Ramp
3: Power Ramp
-
30113/40113 Initial Current 1 R/W 50 – 600 % FLA