Technical information

10 – APPENDIX
148
Appendix B – Fault Codes
See the hardware manual for Troubleshooting Solutions
Fault
Code
Description Controlled Fault
Stop
Shunt Trip
Fault
Auto-Reset
Allowed
F00 No fault - - -
F01 UTS Time Limit Expired Y N Y
F02 Motor Thermal Overload Trip Y N Y
F03 Jog Time Limit Expired N N N
F04 Reserved
F10 Phase Rotation Error, not ABC N N Y
F11 Phase Rotation Error, not CBA N N Y
F12 Low Line Frequency N N Y
F13 High Line Frequency N N Y
F14 Input power not single phase N N Y
F15 Input power not three phase N N Y
F21 Low Line L1-L2 Y N Y
F22 Low Line L2-L3 Y N Y
F23 Low Line L3-L1 Y N Y
F24 High Line L1-L2 Y N Y
F25 High Line L2-L3 Y N Y
F26 High Line L3-L1 Y N Y
F27 Phase Loss N N Y
F28 No Line N N Y
F29 Reserved
F30 I.O.C. N Y N
F31 Overcurrent Y N Y
F34 Undercurrent Y N Y
F35 Reserved
F36 Reserved
F37 Current Imbalance Y N Y
F38 Ground Fault N Y Y
F39 No Current at Run N N Y
F40 Shorted / Open SCR N Y N
F41 Current at Stop N Y N
F47 Stack Protection Fault (stack thermal overload) N N Y
F48 Bypass Contactor Fault Y N N
F50 Control Power Low N N Y
F51 Current Sensor Offset Error - Y N
F52 Burden Switch Error N N N
F53 Reserved
F60 External Fault on DI 1 Input N N Y
F61 External Fault on DI 2 Input N N Y
F62 External Fault on DI 3 Input N N Y
F63 Reserved
F64 Reserved
F71 Analog Input #1 Level Fault Trip (local) Y N Y
F72 Reserved
F73 Reserved
F81 SPI Communication Fault Y N N
F82 Modbus Timeout Fault Y N Y
F94 CPU Error – SW fault N N N
F95 CPU Error – Parameter EEPROM Checksum
Fault
N N
F96 CPU Error N Y N
F97 CPU Error - SW Watchdog N Y N
F98 CPU Error N N N
F99 CPU Error – Program EPROM Checksum Fault N N N