Installation Guide

13
Read
Signal Power On-Status
<CR>*autopower=?#<CR>
NO
Write
Standby Settings-Network on
<CR>*standbynet=on#<CR>
NO
Write
Standby Settings-Network off
<CR>*standbynet=off#<CR>
NO
Read
Standby Settings-Network Status
<CR>*standbynet=?#<CR>
NO
Write
Standby Settings-Microphone on
<CR>*standbymic=on#<CR>
NO
Write
Standby Settings-Microphone off
<CR>*standbymic=off#<CR>
NO
Read
Standby Settings-Microphone Status
<CR>*standbymic=?#<CR>
NO
Write
Standby Settings-Monitor Out on
<CR>*standbymnt=on#<CR>
NO
Write
Standby Settings-Monitor Out off
<CR>*standbymnt=off#<CR>
NO
Read
Standby Settings-Monitor Out
Status
<CR>*standbymnt=?#<CR>
NO
Baud Rate
Write
2400
<CR>*baud=2400#<CR>
NO
Write
4800
<CR>*baud=4800#<CR>
NO
Write
9600
<CR>*baud=9600#<CR>
YES
Write
14400
<CR>*baud=14400#<CR>
YES
Write
19200
<CR>*baud=19200#<CR>
YES
Write
38400
<CR>*baud=38400#<CR>
YES
Write
57600
<CR>*baud=57600#<CR>
YES
Write
115200
<CR>*baud=115200#<CR>
YES
Read
Current Baud Rate
<CR>*baud=?#<CR>
YES
Lamp Control
Read
Lamp
<CR>*ltim=?#<CR>
YES
Read
Lamp2 Hour
<CR>*ltim2=?#<CR>
NO
Write
Normal mode
<CR>*lampm=lnor#<CR>
YES
Write
Eco mode
<CR>*lampm=eco#<CR>
YES
Write
SmartEco mode
<CR>*lampm=seco#<CR>
YES
Write
SmartEco mode 2
<CR>*lampm= seco2#<CR>
YES
Write
SmartEco mode 3
<CR>*lampm= seco3#<CR>
NO
Write
Dimming mode
<CR>*lampm=dimming#<CR>
NO
Write
Custom mode
<CR>*lampm=custom#<CR>
NO
Write
Light level for custom mode
<CR>*lampcustom=value#<CR>
NO
Read
Light level status for custom mode
<CR>*lampcustom=?#<CR>
NO
Read
Lamp Mode Status
<CR>*lampm=?#<CR>
YES
Miscellaneous
Read
Model Name
<CR>*modelname=?#<CR>
YES
Read
System F/W Version
<CR>*sysfwversion=?#<CR>
YES
Read
Scaler F/W Version
<CR>*scalerfwversion=?#<CR>
YES
Read
Format F/W version
<CR>*formatfwversion=?#<CR>
NO
Read
Lan F/W Version
<CR>*lanfwversion=?#<CR>
NO
Read
MCU F/W Version
<CR>*mcufwversion=?#<CR>
YES