Service manual
66
Interface Settings
RS
-
232 protocol
Baud Rate
115200 bps (default)
Changeable settings in User OSD
(2400/4800/9600/14400/19200/38400/57600/115200)
Data Length
8 bit
Parity Check
None
Stop Bit
1 bit
Flow Control
None
Software specification
Software specificationSoftware specification
Software specification
1. When input cmd fail, e.g. correct input is “*pow=?#” but input “*po=?#”, or input “*mute=on#”
while projector is already mute, it will show “*Illegal format#”.
2. When input cmd but projector has no such function item, e.g. input “*sour=RGB2#” but
projector has no RGB2 connector, it will show “*Unsupported item#”.
3. When cmd and function are both workable, but it’s not under the status which cmd can be
executed, e.g. input “*asp=4:3#” while not connecting source, it will show “*Block item#”.
4. When input “query” cmd (with “?”), e.g. input “*sour=?#”, it will echo the same input strings
with some value.
5. Press “Enter” key after” >”, it should be no echo and skip to the next row.
6. Press “Space” and “Enter” key after” >”, it will echo”*Illegal format#”
Command Category
Command CategoryCommand Category
Command Category
Refer to Appendix 2