3.2.10. TEST CONDITIONS
Unless otherwise prescribed, the test conditions are as follows:
. Nominal mains voltage
Temperature: +5~+35
. Warm up time : 30minutes minimum .
. Visual inspection shall be down with the distance from eyes to the sample 35-50 cm .
. Display mode: Primary mode 1920 x 1080
3.2.11. TEST EQUIPMENTS
1. PC with display adapter or other specific
display adapter which is agreed upon by both parties
2. Test program by BenQ
3. Ruler
4. Power saving test tool
5. Minolta color analyzer ( CA-110 or BM – 7 )
3.2.12. VISUAL INSPECTION CRITERIA
1. PACKING
2. ACCESSORIES
3. APPEARANCE
4. AC POWER AND SIGNAL CABLE
5. INTERIOR OF THE PRODUCT
No Description Class
1 Packing
1.1 Wrong packing material Major
1.2 Carton damaged(over 6cm dia).wet, badly taped or stapled, product will not arrive
in good condition at customer
Minor
1.3 Carton damaged(3cm to 6cm dia), badly taped or stapled , product will arrive in
good condition at customer
Minor
1.4 Wrong marking of trade mark Major
1.5 Wrong marking of model number Major
1.6 Wrong serial # marking on carton Major
1.7 Product wrongly placed in box ( upside down ) Major
1.8 Broken polyfoam or PU foam Major
1.9 Broken packing bag Major
1.10 Wrong size or poor printing for artwork/character Major
1.11 Bar-code wrong, missing, or damaged Major
1.12 Label on box missing or damaged Major
1.13 Strange object in the box Major
1.14 Unit not corresponding to model stated on external label Major
1.15 Superficial breaking 5 ~ 10 cm dia Minor
2 Accessories
2.1 Missing accessory parts Major
2.2 Wrong Accessory parts Major
3 Appearance of product
3.1 Incorrect color of cabinet Major
3.2 Incorrect color of tilt/swivel base Major
3.3 Wrong logo or name plate Major