Datasheet

6
BENNING BENNING BENNING BENNING BENNING BENNING BENNING BENNING
CC 1 CC 3 CM 1-1 CM 1-2 CM 1-3 CM 3 CM 4 CM 6
indicating range 2000 2000 2000 2000 4000 4000
basic accuracy 1.9 % 1 % – 2 % 2 % 1 % 1 % 1.9 % 0.7 % 0.7 %
AC voltage 0.1 V – 600 V 0.1 V – 750 V 0.1 V – 600 V 0.1 V – 750 V
DC voltage 0.1 V – 600 V 0.1 V – 1000 V 0.1 V – 600 V 0.1 V – 1000 V
AC current 1 A – 400 A 0.2 A – 300 A 10 mA – 400 A 0.1 A – 400 A 0.1 A – 200 A 0.1 A – 600 A 0.1 A – 600 A 0.1 A – 1000 A
DC current 0.2 A – 300 A 0.1 A – 600 A
resistance 0.1 Ω – 20 MΩ 0.1 Ω – 20 MΩ 0.1 Ω – 400 Ω 0.1 Ω – 400 Ω
continuity/diode –/– –/– –/– yes/– yes/yes –/– yes/– yes/–
frequency 1 Hz – 400 Hz 1 Hz – 400 Hz
effective power
power factor (cos φ)
temperature
volt sensor yes
memory
HOLD, MAX
HOLD
HOLD
HOLD
HOLD, MAX/MIN,
HOLD, MAX/MIN,
PEAK PEAK
measuring method
RMS RMS RMS RMS RMS RMS
max. clamp opening
30 mm 25 mm 30 mm 30 mm 16 mm 38 mm 37 mm 53 mm
measuring category
CAT III 300 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V CAT III 300 V CAT III 600 V CAT IV 600 V
item no. 044037 044038 044061 044062 044063 044031 044056 044058
Digital Current Clamp Multimeter/Current Clamp Adapter
output: 1 mV AC per
1 A AC
suitable for BENNING ...
MM 1-1/1-2/1-3/2/3,
MM 5-1/5-2/7-1/9/10/11,
IT 130
output: 1 mV/10 mV AC/DC
per 1 A AC/DC
suitable for BENNING ...
PV 1-1, MM 1-1/1-2/1-3,
MM 2/3/5-1/5-2/7-1/9/10/11,
IT 130
CC 3 CC 1
CM 2
CM 3
B E N N I N G W o r l d C l a s s T e s t E q u i p m e n t
BENNING CM 1-1, CM 1-2, CM 1-3, CM 4 and CM 6
Digital Current Clamp Multimeter for AC current
Innovative technology, practical design
• safe current measuring up to max. 1000 A AC
• measuring inputs for voltage, resistance, continuity and
diode test
• integrated volt sensor signalises phase voltages by means
of an acoustic signal and a red LED signal (CM 1-3)
• it localizes cable breaks and defective lamps in exposed
cables (cable reel, light chains) via the feeding side of the
phase (CM 1-3)
BENNING CM 2 and CM 3
Digital Current Clamp Multimeter for
AC/DC current
• safe and non-contact measuring of high currents
• DC and AC current measuring up to 600 A AC/DC
• measurement of low currents (automotive, photovoltaics,
industry) (CM 2)
• measuring inputs for voltage, resistance and continuity
test (CM 2)
• precise due to TRUE RMS measuring method (CM 2)
Digital Current Clamp Multimeter
for AC/DC current
Our
best seller!
TRUE RMS
volt sensor
CAT IV 600 V
CM 1-3
CM 1-2
CM 1-1
BENNING CC 1 and CC 3
AC and AC/DC current clamp adapters
• safe current measuring up to max. 400 A AC
• connection via 4 mm safety measuring leads
tested and
approved
IEC/EN 61010-1
(DIN VDE 0411-1)